SEL90M28G (FE 2.8/90 MACRO G OSS) (FE 90mm F2.8 Macro G OSS)
4-3
4. The folder select screen appears, then select the installing user and click the [Next] button.
Everyone:
For all users of the PC for installing.
Just me:
Only for the user who logs in the PC now.
Fig. 4-2-3
5. The installer start up screen appears, then click the [Next] button to start the installation.
Fig. 4-2-4
6. The following screen appears when the installation is complete, then click the [Close] button.
Fig. 4-2-5
7. Create a shortcut icon of the E-Mount Lens Adjustment (Adjustment Application for Service) on the desk top.
Fig.
4-2-6
4-3. E-MOUNT LENS ADJUSTMENT
4-3-1. Method for Starting and Finishing the E-Mount Lens Adjustment
(1) Starting the E-Mount Lens Adjustment
* After replacing the Optical Block For Service, click the [Service Flag OFF (S)] button to release the specified flag before using the E-Mount
Lens Adjustment. (Refer to “
1-5. NOTE ON REPLACEMENT OF OPTICAL BLOCK FOR SERVICE
”.)
* Make sure to disconnect the AC adaptor after finishing the adjustment (including the case when stops due to an error).
* SeusEX will start when the E-Mount Lens Adjustment is started.
1. Turn on the power of camera.
2. Start the E-Mount Lens Adjustment.
3. The camera selection window opens, and select “ILCE-5000”.
* Only ILCE-5000 cameras are available for the adjustment of the unit.
Fig.
4-3-1
4. Click the [Connect] button and check that the connection status becomes “Connect”.
Fig.
4-3-2