SEL2470GM (FE 2.8 / 24-70 GM) (FE 24-70mm F2.8 GM)
4-9
14. Confirm that abnormal noise from a lens is not heard.
Push the ENTER key.
Fig.
4-3-23
15. After completing the adjustment, “RESONANCE NOISE CHECK OK” is displayed.
Fig.
4-3-24
16. Recording the adjustment data and releasing the adjustment mode are performed automatically by pushing the ENTER key. After processing,
“FINISHED” is displayed.
(4) Adjustment method of “ROM Check”
About “ROM Check” item, the operation of lens side is needed.
Note:
Be sure to move the zoom to TELE end, start the adjustments.
When operating the lens, operate it while holding a camera body by hand well.
So that a lens does not work. And never touch the focus ring.
1. Click the [ROM Check] button, “ZOOM set to [WIDE].” is displayed. Rotate the zoom ring to the WIDE end, push the ENTER key.
Fig.
4-3-25
2. After completing the adjustment, “SW CHECK OK” is displayed.
Fig.
4-3-26
3. Recording the adjustment data and releasing the adjustment mode are performed automatically by pushing the ENTER key. After processing,
“FINISHED” is displayed.