background image

Sony Corporation

Revision History

SERVICE MANUAL

Link (English)

 

SPECIFICATIONS

 

DISASSEMBLY

 

SERVICE NOTE

 

REPAIR PARTS LIST

 

ADJUSTMENTS

Link (Japanese)

 

SPECIFICATIONS

 

DISASSEMBLY

 

SERVICE NOTE

 

REPAIR PARTS LIST

 

ADJUSTMENTS

SEL1018 (E 4/10-18 OSS) (E 10-18mm F4 OSS)

983470513.pdf

2017C08-1

  © 2017.03

Published by Sony Techno Create Corporation

INTERCHANGEABLE LENS

9-834-705-13

Ver.

Date

History

Contents

S.M. Rev.

issued

1.0

2012.11

Official Release

1.1

2016.12

Revised-1
(A1 16-079)

• Change of DISASSEMBLY.
 English: Page 

2-2

2-5

 Japanese: Page 

2-2

2-5

• Addition of DISASSEMBLY.
 English: Page 

2-3

2-6

 Japanese: Page 

2-3

2-6

• Change of REPAIR PARTS LIST.
 Page 

3-1

3-2

• Addition of Section 4. ADJUSTMENTS.
 English: Page 

4-1

 Japanese: Page 

4-1

Yes

1.2

2017.03

Revised-2
(A2 15-173)

• Revision of ADJUSTMENTS.
 English: Page 

4-1

 Japanese: Page 

4-1

Yes

SEL1018

     (E 4/10-18 OSS) (E 10-18mm F4 OSS)

Ver. 1.2  2017.03

US Model

Canadian Model

AEP Model

Chinese Model

Japanese Model

分解図につきましては,英語版を
ご参照下さい。

Revision History

Revised-2

Replace the previously issued
SERVICE MANUAL 9-834-705-12
with this Manual.

Summary of Contents for SEL-1018

Page 1: ...al Release 1 1 2016 12 Revised 1 A1 16 079 Change of DISASSEMBLY English Page 2 2 2 5 Japanese Page 2 2 2 5 Addition of DISASSEMBLY English Page 2 3 2 6 Japanese Page 2 3 2 6 Change of REPAIR PARTS LIST Page 3 1 3 2 Addition of Section 4 ADJUSTMENTS English Page 4 1 Japanese Page 4 1 Yes 1 2 2017 03 Revised 2 A2 15 173 Revision of ADJUSTMENTS English Page 4 1 Japanese Page 4 1 Yes SEL1018 E 4 10 1...

Page 2: ...ith an APS C sized image sensor 2 Minimum focus is the shortest distance from the image sensor to the subject Depending on the lens mechanism the focal length may change with any change in shooting distance The focal lengths given above assume the lens is focused at infinity Included items Lens 1 Front lens cap 1 Rear lens cap 1 Lens hood 1 Set of printed documentation Design and specifications ar...

Page 3: ... 1 4 SAFETY CHECK OUT After correcting the original service problem perform the following safety checks before releasing the set to the customer 1 Check the area of your repair for unsoldered or poorly soldered connections Check the entire board surface for solder splashes and bridges 2 Check the interboard wiring to ensure that no wires are pinched or contact high wattage resistors 3 Look for una...

Page 4: ...ersal wrench J 6082 609 1 Chip B for universal wrench J 6082 609 2 Attach the chip A or chip B to the universal wrench For the notches For the holes UNIVERSAL WRENCH In case of the following notches or holes are located in the lens block etc during disassembling assembling the lens Use the universal wrench chip A chip B Notches Holes Chip Chip A Chip A Chip B Chip B Chip Match the universal wrench...

Page 5: ...he equivalent qf qd qg F E D C D E F C 1 2 3 4 5 6 7 8 Ornamental Plate F Lock Pin Front Tube Assy Focus Ring Assy Zoom Ring Assy Rear Tube Assy CL 1002 Board PC Board Rubber Damper Vibration Proofing Sheet FB Washer GP Mount Rear Tube Contact Block Assy Stopper Screw Fixed Tube Block PI Fixed Plate Adhesive Tape Filter Screw Frame See Page 2 3 qa qs 9 HELP03 HELP02 HELP01 q HELP04 HELP05 Note The...

Page 6: ...2 3 SEL1018 E 4 10 18 OSS E 10 18mm F4 OSS 2 2 DISASSEMBLY 2 2 Group Service Assy 4 Group Mask Cam Tube Straight Tube Vibration Proof Service Assy 1 Group Assy 1 HELP06 3 HELP08 HELP07 2 Ver 1 1 2016 12 ...

Page 7: ...side 2 Check operation of the Zoom Ring Assy Zoom Ring Assy Zoom Ring Assy inside Entrance part of groove B Groove Groove Zoom potentio lever Cam Tube Coma Screw Cam Tube Coma Screw HELP03 Adhesive bond B 110 J 6082 617 A 1 Assemble Front Tube Assy by fitting the phases at the three places of Bayonet and fitting the direction of the mounting hole of the F lock pin 2 Turn Front Tube Assy in the dir...

Page 8: ...th cutout of the optical block and then tighten three screws Filter Screw Frame Optical Block Optical Block Filter Screw Frame back side Cutout Projection Ver 1 1 2016 12 HELP06 1 Match the groove of 2 Group Service Assy to the Coma of 1 Group Assy and assemble them 2 Rotate the 1 Group Assy to the fully counterclockwise direction Groove Coma 2 Group Service Assy 1 Group Assy 3 Attach the each fle...

Page 9: ...places 4 Rotate the Straight Tube to the fully counterclockwise direction Straight Tube Grooves 2 Group Service Assy Projections HELP08 1 Pass the flexible board of Vibration Proof Service Assy through the hole of 2 Group Service Assy 2 Tighten the three screws Hole Flexible Board 2 Group Service Assy Vibration Proof Service Assy Ver 1 1 2016 12 ...

Page 10: ...1 01 102 ORNAMENTAL PLATE 4 4 447 423 01 188 ADHESIVE TAPE 5 4 159 676 01 F LOCK PIN 6 4 451 557 01 101 FILTER SCREW FRAME 7 2 699 027 01 BT2P1 7X5C3C 8 4 451 665 01 A09 FRONT TUBE ASSY 9 4 451 666 01 A10 FOCUS RING ASSY 10 4 292 414 01 113 PLATE PI FIXED 11 4 451 667 01 A11 ZOOM RING ASSY 12 4 451 668 01 A12 REAR TUBE ASSY 13 4 409 954 01 SCREW GP MOUNT STOPPER 14 4 208 815 01 BT1P2X4C3C 15 4 209...

Page 11: ...ナ語 中国語 繁体字 韓国語 アラビア語 Ref No Part No Description 901 X 2582 781 1 Front lens cap 902 4 159 701 03 Rear lens cap 903 4 443 499 01 Lens hood 904 4 440 877 01 Instruction Manual JAPANESE ENGLISH FRENCH SPANISH SIMPLIFIED CHINESE 904 4 440 877 11 Instruction Manual GERMAN DUTCH SWEDISH ITALIAN PORTUGUESE 904 4 440 877 21 Instruction Manual RUSSIAN UKRAINIAN TRADITIONAL CHINESE KOREAN ARABIC 付属品 951 952...

Page 12: ... z z z z Resolving Power Check Adjustment z z z z E Mount Lens Adjustment Lens Device S z z z z Flange Back S z z z z F Number S z z Gyro Sensor S z z Rom Check z z z z z z Lens Sleep z z z z z z 4 1 2 Adjustment Check Order Flowchart After Replacing Parts Check the optical axis Section 4 2 2 Check the resolving power Section 4 3 Check the resolving power Section 4 3 NG Check the optical axis Sect...

Page 13: ...r more recommended Windows 7 1 GB or more recommended Windows Vista USB port USB 2 0 recommended also compatible with 1 1 Two connectors are required Run time NET Framework 2 0 NET Framework 2 0 is installed at lens adjustment program installation if it is not installed J 1 J 4 J 2 J 3 J 9 J 5 J 17 J 18 J 20 J 19 J 6 J 7 J 8 J 16 J 15 J 10 J 11 J 12 J 14 J 13 HASP key SeusEX Flange back adjustment...

Page 14: ... fine scratches are the sharpest Note Turn the knob in the direction of the arrow of figure below for correct reading Focusing knob Focus on fine lines on the surface Always turn the knob in the arrow direction for correct reading 5 Turn the scale ring of the dial gauge until the long pointer indicates 0 Note This position is the flange back f F 43 50 mm Memorize the position of the short pointer ...

Page 15: ...nd extract it 2 Save BLG TestProgramV exe in an any folder Note The version of BLG TestProgram may be updated without notice 5 When starting and finishing the BLG TestProgram perform the following procedure Starting the BLG TestProgram Starting Procedure 1 Mount the checking lens to the lens mount block 2 Connect the D sub 15 pin cable to the lens mount block and turn on the B L Control Box 3 Star...

Page 16: ... and click Steady Shot 10 Select Open from the iris selection menu and click Iris Steady Shot setting Center Hold Iris setting Open 11 To change the zoom position with the zoom lens set the zoom position to the specified value Manual zoom Set the zoom position manually Motorized zoom Set the focal length and zoom speed from the lens adjustment program and click Zoom Focal Dist If a time out error ...

Page 17: ...or less 0 06 mm or less 3 If the specifications are not satisfied replace the 2 Group Service Assy Then perform the 4 2 2 Optical Axis Check again Note If cannot be resolved even after replacing the 2 Group Service Assy replace the Optics Unit For Service 4 3 RESOLVING POWER CHECK 4 3 1 Setting Preparation of the Lens Test Projector F Preparations of Using a Camera General E mount Interchangeable ...

Page 18: ...ount attachment Lens to be tested Plane mirror Screen USB to Serial Cable D sub 9 pin Female RS 232C Cable AC Cable D sub 9 pin Male B L Control Box Personal computer D sub 15 pin cable 6 Install the BLG TestProgram in the following procedure 1 Download the file BLG TestProgramV zip save and extract it 2 Save BLG TestProgramV exe in an any folder Note The version of BLG TestProgram may be updated ...

Page 19: ...he screen and confirm again that the reflected light illuminates the center of the lens to be tested If the reflected light position is deviated re adjust the Lens Test Projector F position 6 Select Open from the iris selection menu and click Iris Steady Shot setting Center Hold Iris setting Open 7 To change the zoom position with the zoom lens set the zoom position to the specified value Manual z...

Page 20: ...er of projective resolving power lines maximum resolving power of the center projected image y 0 5 Read the value the number of projective resolving power lines of the thinnest line resolution limit that allows recognition of contrast of the sagittal S image and meridional M image three lines of the peripheral projected image y 10 12 Note Be careful of spurious resolution when checking the resolut...

Page 21: ...ce position 100 mm of step 1 then shoot two times with self timer 4 Check the three images to see if the resolution of the patterns in four corners meets the standard shown in the below 1125mm x 750mm 3 2 2015 12 15 LENS Gp 0 8 0 6 0 5 0 3 0 3 0 5 0 6 0 8 Check the center circle red frame and the other peripheral circles blue frame at the same magnification Note Check if the circle in the center i...

Page 22: ...SB connector Checking Lens Checking Lens Personal computer Within 10 mm In the case of fixed focal lens In the case of zoom lens Within 10 mm Flange back adjustment jig FB chart 10 mm AC adaptor Flange back adjustment jig Flange back adjustment jig Installing Procedure Note Make sure to perform the installation only by the management Do not change the folder to be installed in 1 Download the lens ...

Page 23: ...es displayed on the Message History window will be deleted 4 5 3 Method for Starting and Finishing Method for Starting the E Mount Lens Adjustment After replacing the Optics Unit For Service click the Service Flag OFF S button to release the specified flag before using the E Mount Lens Adjustment Refer to 1 5 NOTE ON REPLACEMENT OF OPTICS UNIT FOR SERVICE Make sure to disconnect the AC adaptor aft...

Page 24: ...nt method of Flange Back S About Flange Back S item the operation of lens side is needed Note Be sure to move the zoom to TELE end start the adjustments When operating the lens operate it while holding a camera body by hand well So that a lens does not work And never touch the focus ring 1 Click the Flange Back S button to display he START screen After completing the preparation of adjustments pus...

Page 25: ...f lower Tolerance of setting value is 2 When the adjustment value on the left lower window is reached to the tolerance of setting value background color of adjustment value is changed to blue Note When operating the zoom ring operate it slowly so that the adjustment value on the left lower window does not exceed the side tolerance of setting value If it exceeds side tolerance of setting value the ...

Page 26: ...半田こてのこて先は 必ず無鉛半田用と有鉛半田用に分けて管理してください 無鉛半田と有鉛半田が混在すると剥離現象が発生してしまいます 1 4 SAFETY CHECK OUT サービス 点検時には次のことにご注意ください 1 注意事項をお守りください サービスのとき特に注意を要する個所については キャビネッ ト シャーシ 部品などにラベルや捺印で注意事項を表示しています これら の注意書き及び取扱説明書等の注意事項を必ずお守りください 2 指定部品のご使用を セッ トの部品は難燃性や耐電圧など安全上の特性を持ったものとなっています 従って交換部品は 使用されていたものと同じ特性の部品を使用してください 特に回路図 部品表に0印で指定されている安全上重要な部品は必ず指定のものをご使用ください 3 部品の取付けや配線の引きまわしはもとどおりに 安全上 チューブやテープなどの絶縁材料を使用したり ...

Page 27: ...さい フレキシブル基板のメッキ部に過度な負担をかけないでください 切り欠き 穴 使用方法 レンズ専用治具について 分解 または組み立て時に レンズブロック等に以下のような切り欠き または穴がある場合は レンズ専用治具を使用してください レンズ専用治具 J 6082 609 A レンズ専用治具 チップA J 6082 609 1 レンズ専用治具 チップB J 6082 609 2 レンズ専用治具にチップA またはチップBを取り付ける 切り欠き用 穴用 チップA チップB レンズ専用治具 切り欠き 穴 チップ チップ 切り欠き または 穴の幅に合わせて 調節する 下図のようにレンズ専用治具をレンズブロック等の穴 または切り欠きに合わせて使用する チップA チップA チップB チップB 副資材について B 110 ボンド B 110 J 6082 617 A ボンド ロックタイト460 または相...

Page 28: ...f qd qg F E D D E F C C 1 2 3 4 5 6 7 8 q CL 1002 基板 基板ダンパーゴムB 基板防振シート 後環Assy ズームリングAssy フォーカスリングAssy 固定環Assy Note Note 化粧板 化粧板粘着剤 フィルターネジ枠 See Page 2 3 前環ロックピン 前環Assy ストッパービス 接点ブロック Assy 後遮光筒 qa qs GPマウント FBワッシャー PI固定板 9 HELP04 HELP03 HELP02 HELP05 HELP01 ロックタイト460 または相当品 The changed portions from Ver 1 0 are shown in blue Ver 1 1 2016 12 ...

Page 29: ...2 3 SEL1018 E 4 10 18 OSS E 10 18mm F4 OSS 2 2 DISASSEMBLY 2 2群サービスAssy 4群マスク カム筒 直進筒 防振サービスAssy 1群Assy 1 HELP06 3 HELP08 HELP07 2 Ver 1 1 2016 12 ...

Page 30: ...ームポテンショレバー カム筒コマビス2個所とズームリングAssy 内側 の溝A 2個所 の位置を合 わせてズームリングAssyを取り付ける 2 ズームリングAssyを回転し 動作確認を行う ズームリングAssy ズームリングAssy 内側 カム筒コマビス 溝A 溝A カム筒コマビス ズームポテンショレバー 溝B入口 HELP03 ボンド B 110 J 6082 617 A 1 バヨネッ ト 3箇所 の位相と前環ロックピン取り付け穴の向きを合わせて 前環Assyを組み付ける 2 前環ASSYを矢印方向に回転させて 前環ロックピンの挿入口を合わせる 3 前環ロックピンを取り付ける 4 ボンド B 110 を指示部に塗布する バヨネット ボンド B 110 を塗布 前環Assy 前環ロックピン 前環ロックピン ...

Page 31: ...ネジ枠 化粧板 裏面 切り欠き 凸部 HELP05 フ ィルターネジ枠Assy 裏面 の凸部と光学部組の切り欠きの位置を合わせてフ ィルターネジ枠Assyを取り付け ねじ3本を締め付ける 光学部組 フィルターネジ枠Assy フィルターネジ枠Assy 裏面 光学部組 切り欠き 凸部 Ver 1 1 2016 12 HELP06 1 2群サービスAssyの溝に1群Assyのコマを合わせて取り付ける 2 1群Assyを反時計方向いっぱいに回す 溝 コマ 2群サービスAssy 1群Assy 3 各フレキシブル基板をそれぞれの溝に収める 溝 フレキシブル基板 フレキシブル基板 HELP07 1 カム筒の溝に直進筒の凸部を合わせて取り付ける 3箇所 2 カム筒を時計方向いっぱいに回す 溝 凸部 カム筒 直進筒 ...

Page 32: ... E 4 10 18 OSS E 10 18mm F4 OSS 3 直進筒の溝に2群サービスAssyの凸部を合わせて取り付ける 3箇所 4 直進筒を反時計方向いっぱいに回す 直進筒 溝 2群サービスAssy 凸部 HELP08 1 2群サービスAssyの穴に防振サービスAssyのフレキシブル基板を通す 2 ねじ3本を取り付ける 穴 フレキシブル基板 2群サービスAssy 防振サービスAssy Ver 1 1 2016 12 ...

Page 33: ...基板 フォーカスリングAssy ズームリングAssy 光軸の確認 解像力の確認 調整 E Mount Lens Adjustment Lens Device S Flange Back S F Number S Gyro Sensor S Rom Check Lens Sleep 4 1 2 調整 確認手順フローチャート 部品交換後 光軸の確認 4 2 2項 解像力の確認 4 3項 解像力の確認 4 3項 NG NG 解像力の調整 4 4項 NG OK OK OK Lens Device S サービス専用光学ユニッ トを交換 Flange Back S F Number S レンズ調整プログラム E Mount Lens Adjustment 4 5項 終了 Gyro Sensor S Rom Check Lens Sleep 光軸の確認 4 2 2項 NG OK 2群サービス Assyを...

Page 34: ... でも使用可能 ポートは2個必要 Run time NET Framework 2 0 NET Framework 2 0がインストールされていないPCには レンズ調整プログラムインストー ル時にインストールされます J 1 J 4 J 2 J 3 J 6 J 7 J 9 J 8 J 5 J 17 J 16 J 18 J 15 J 20 J 19 J 10 J 11 J 12 J 14 J 13 HASPキー SeusEX フランジバック 調整用治具 J 6082 563 A 調整用アプリケーション SeusEX とHASPキー の入手については ソニー サービスステーションに 問合せてください ACアダプター AC PW20 1 487 963 12 EXCEPT US CND 1 487 963 22 US CND 1000 mmコリメータ 110V J 6082 604 A 240V...

Page 35: ... 3 フランジバックゲージ 43 50 mm をAマウントアタッチメントに密着させ 保持する 4 フランジバックゲージに光を投じながらフランジバック測定器のノブを回転させて 細かい線が出るようにピントを合わせる 注意 必ず下図の矢印方向にピント合わせを行ってください ノブ 中心付近の細かい線に ピントを合わせる ピント合わせ方向 5 ダイヤルゲージの目盛りリングを回して ダイヤルゲージの指針を 0 に合わせる 注意 この位置がフランジバック値 fʼF 43 50 mmとなります 短針の位置を記憶しておいてください カメラ Eマウントレンズ交換式デジタルカメラ全般 を使用する場合の準備 使用機器 治工具 Eマウント延長治具 カメラ Eマウントレンズ交換式デジタルカメラ全般 使用機器 治工具の設定手順 1 AマウントアタッチメントにA E変換アタッチメントとEマウント延長治具を取り付け 下図の...

Page 36: ...G TestProgramをインストールする 1 BLG TestProgramV zip をダウンロードして解凍する 2 BLG TestProgramV exe を任意のフォルダに保存する 注意 BLG TestProgram のバージョンは更新されることがあります 5 BLG TestProgramの起動と終了は 次の手順で行う BLG TestProgramの起動 起動手順 1 被検レンズをレンズマウント部にマウントする 2 D sub 15ピンケーブルをレンズマウント部に接続し B L コントロールボックスの電源を入れる 3 BLG TestProgramV exe を起動する 4 Open をクリックしてB L コントロールボックスとの通信を接続する 注意 使用するB L コントロールボックスまたはパソコンで初めて起動した場合は パスワードの入力が必要となります パスワード入力...

Page 37: ...Dが消灯したことを確認してから外してください 9 手振れ選択メニューより Center Hold を選択し Steady Shot をクリックする 10 絞り選択メニューより Open を選択し Iris をクリックする 手振れ設定 Center Hold 絞り設定 Open 11 ズーム位置を変更する場合は 指定された値にズーム位置を設定する 手動ズーム 手動にてズーム位置を設定する 電動ズーム レンズ調整プログラムより焦点距離とズーム速度を設定し Zoom Focal Dist をクリックする タイムアウトエラーになる場合はズーム速度を上げてください ズーム開始ボタン ズーム速度選択 焦点距離入力 入力時は左のプルダウンで Input を選択 焦点距離選択 12 フォーカスメニューより を選択する 注意 フォーカス設定用ボタンは機種により異なります こちらは使用しない OFFにする こ...

Page 38: ...規格値 参考値 CB センターブレ AS 軸上アス 0 09 mm 以下 0 06 mm 以下 3 規格値を満足していない場合は 2群サービスAssyを交換して 再度 4 2 2 光軸の確認 を行う 注意 2群サービスAssyを交換しても改善しない場合は サービス専用光学ユニットを交換してください 4 3 解像力の確認 4 3 1 レンズ投影機の設置 準備 カメラ E マウントレンズ交換式デジタルカメラ全般 を使用する場合の準備 使用機器 治工具 レンズ投影機 スクリーン 巻尺 平面ミラー SLR用等 カメラ Eマウントレンズ交換式デジタルカメラ全般 Eマウント延長治具 レンズ投影機用 E Mount APSC治具 Eマウントアタッチメント 注意 レンズ投影機に被検レンズのタイプ FF APSC に合ったレンズ投影機用E Mount APSC治具とEマウントアタッチメントを取り付けてくださ...

Page 39: ...ount APSC治具 USB to シリアルケーブル D sub 9ピン メス RS 232Cケーブル ACコード D sub 9ピン オス B L コントロールボックス パーソナルコンピュータ D sub 15ピン ケーブル 6 次の手順でBLG TestProgramをインストールする 1 BLG TestProgramV zip をダウンロードして解凍する 2 BLG TestProgramV exe を任意のフォルダに保存する 注意 BLG TestProgram のバージョンは更新されることがあります BLG TestProgramの起動と終了方法 BLG TestProgramの起動 起動手順 1 被検レンズをレンズマウント部にマウントする 2 D sub 15ピンケーブルをレンズマウント部に接続し B L コントロールボックスの電源を入れる 3 BLG TestProgra...

Page 40: ...り Center Hold を選択し Steady Shot をクリックする 5 スクリーン上の中心投影像に平面ミラーを重ね合わせ 反射光が被検レンズの中心を照らしていることを再確認する もし位置 がずれている場合はレンズ投影機の位置を調整する 6 絞り選択メニューより Open を選択し Iris をクリックする 手振れ設定 Center Hold 絞り設定 Open 7 ズーム位置を変更する場合は 指定された値にズーム位置を設定する 手動ズーム 手動にてズーム位置を設定する 電動ズーム レンズ調整プログラムより焦点距離とズーム速度を設定し Zoom Focal Dist をクリックする タイムアウトエ ラーになる場合はズーム速度を上げてください ズーム開始ボタン ズーム速度選択 焦点距離入力 入力時は左のプルダウンで Input を選択 焦点距離選択 8 フォーカスメニューから JOG...

Page 41: ...る 参考値 の表を参照 2 フォーカスを設定する 3 スクリーン上の中心投影像 y 0 が出来るだけ細かな線まで鮮明に見えるようにピントを合わせる S像 小さな投影像 高周波用 を 使用する M像 解像力本数 4 中心投影像 y 0 の投影解像力本数 最高解像力 の数値 投影解像力本数 を読み取る 5 周辺投影像 y 10 12 のサジタル S 像 およびメリジオナル M 像 3本の線 の明暗が確認可能な最も細かな線 解像限界 の数 値 投影解像力本数 を読み取る 注意 解像限界確認時は 偽解像に注意してください 偽解像とは解像力を超えた細かな線が あたかも解像しているかのように黒 白の条線として見える現象です この場合 下図のように3本の条線の白黒が反転して2本または4本に見えることがありますので 解像限界と混同しないように注意して ください 正常 偽解像 6 被検レンズの焦点距離および...

Page 42: ...アルフォーカスに設定する 2 ピントを合わせて セルフタイマーで撮影する 3 ピントは手順2の状態のままで 撮影距離を手順1の位置から 100 mmの位置にし 2枚セルフタイマーで撮影する 4 撮影画像3枚の結果から 周辺の解像が以下の基準を満たしているか確認する 中心 赤枠 のサークルと中心以外 青枠 のサークルを等倍で確認してください 1125mm x 750mm 3 2 2015 12 15 LENS Gp 0 8 0 6 0 5 0 3 0 3 0 5 0 6 0 8 注意 中心のサークルが解像していることを確認し 周辺のサークル 24個 は上下左右が均等に解像していることを確認してください 任意のサークルその直径方向で反対にあるサークルは同等に解像されていること Adobe Photoshop等を使用して 解像の確認を行ってください 4 4 解像力の調整 4 4 1 解像力 片ボ...

Page 43: ...します フランジバック 調整用治具 10 mm以内 ズームレンズの場合 単焦点レンズの場合 被検レンズ フランジバック 調整用治具 10 mm以内 被検レンズ パーソナルコンピュータ USBケーブル カメラ 三脚 任意 被検レンズ ACアダプター フランジバック 調整用治具 FBチャート 10 mm HASPキー USBコネクタへ USBコネクタへ AC 三脚ネジへ インストール手順 注意 インストールは 管理者権限で行ってください インストール先フォルダは変更しないでください 1 レンズ調整プログラム E Mount Lens Adjustment zip をダウンロードする 2 setup exeをダブルクリックする 3 インストーラー画面が表示されるので 次へ ボタンをクリックする 4 インストール先フォルダを選択する画面が表示されるので インストールするユーザーを選択して 次へ ボ...

Page 44: ...スリングを触らないでください 調整結果はMessage Historyに表示されます Clear ボタンをクリックすると Message Historyに表示されている履歴が消去されます 4 5 3 起動と終了方法 E Mount Lens Adjustmentの起動方法 サービス専用光学ユニット交換後にE Mount Lens Adjustmentを使用する際は Service Flag OFF S ボタンをクリックして フラ グ解除を実施してください 1 5 サービス専用光学ユニット交換時の注意 参照 調整終了後 エラーでの終了時も含む は 必ずACアダプターの脱着を行ってください E Mount Lens Adjustmentを起動するとSeusEXも起動します 起動手順 1 カメラの撮影モードをP プログラムオート にして 電源を入れる 2 E Mount Lens Adjustm...

Page 45: ...の電源を切る 4 5 4 各項目の調整方法 調整方法 1 Adjustment and Inspectionから 該当する調整項目のボタンをクリックする Flange Back S の調整方法 Flange Back S の項目については レンズ側での操作が必要となります 注意 必ずズームをTELE端にしてから 調整を開始してください レンズ操作時は レンズの位置が動かないように カメラ本体等をしっかりと手で保持しながら操作してください その際に フォーカスリングには絶対に触れないでください 1 Flange Back S ボタンをクリックするとSTART画面が表示されるので 調整の準備が完了したらENTERキーを押す 2 画面が ZOOM WIDE の表示に変わったら ズームリングをWIDE端まで回してENTERキーを押すとWIDE端の自動調整を開始す る 3 自動調整が正常に終わると ...

Page 46: ...部のバーと数値 16進数 はズームリングの動きと連動して表示されます ウインドウ下部のバーにも設定値の目安となる緑色のラインが表示されます 設定値の許容範囲は 2です ウインドウ左下の調整値が設定値の許容範囲内に達すると 調整値の背景色が水色に変化します 注意 ズームリングを操作する際に ウインドウ左下の調整値が設定値の 側許容範囲を超えないよう ゆっくりと操作してください 設定 値の 側許容範囲を超えてから許容範囲内に数値を戻してもエラーとなります 7 ENTERキーを押す 8 上記の手順6 7の操作を POS4 まで繰り返す 9 調整が完了すると FB ADJUSTMENT OK と表示される 10 ENTERキーを押すと自動的に調整データの記録と調整モードの解除が行われ 処理が終わると FINISHED のメッセージが表示さ れる ...