19
ESD
Discharge
< 15 kV: No operation failure
Voltage
< 20 kV: No drive damage
Air-cooling Requirement
Surrounding temperature
< 40 ˚C
Clean air flow is recommended to minimize the possibility of data loss.
Temperature and Humidity Range
Temperature
Operating
5 ˚C to 40 ˚C (
∆
T<10 ˚C/h)
Non-Operating (mech.)
– 40 ˚C to 70 ˚C (
∆
T<20 ˚C/h)
Non-Operating (tape)
– 40 ˚C to 45 ˚C (
∆
T<20 ˚C/h)
Humidity
Operating
20 to 80% RH, non-condensing
Maximum wet bulb temperature = 26 ˚C
Non-Operating (mech.)
5 to 95% RH (
∆
T<30%/h)
Non-Operating (tape)
20 to 80% RH (
∆
T<30%/h)
Power Requirements
Model
Voltage
Max Ripple
Current
Typical
Maximum
SDX-420 series
5 V +/– 5 %
100 mVp-p
1.4 A
2.5 A
12 V +/– 10 %
150 mVp-p
0.45 A
1.2 A
SDX-520 series
5 V +/– 5 %
100 mVp-p
1.5 A
2.5 A
12 V +/– 10 %
150 mVp-p
0.45 A
1.2 A
Suspended Particulate
Operating
Less than 150 microgram/m
3
Based Sampling period 24 hours