30
Power Requirements
SDX-450V
Voltage
Max Ripple
Current
Typical
Maximum
5 V +/– 5 %
100 mVp-p
1.1 A
1.4 A
12 V +/– 10 %
150 mVp-p
0.4 A
1.2 A
SDX-250V
Voltage
Max Ripple
Current
Typical
Maximum
5 V +/– 5 %
100 mVp-p
1.1 A
1.4 A
12 V +/– 10 %
150 mVp-p
0.4 A
1.2 A
Air-cooling Requirement
Surrounding temperature
< 40 ˚C (104 ˚F)
Clean air flow is recommended to minimize the possibility of data loss.
Temperature and Humidity Range
Temperature
Operating
5 ˚C to 40 ˚C (
∆
T<10 ˚C/h)
(41 ˚F to 104 ˚F (
∆
T<18 ˚F/h))
Non-Operating (mech.)
– 40 ˚C to 70 ˚C (
∆
T<20 ˚C/h)
(– 40 ˚F to 158 ˚F (
∆
T<36 ˚F/h))
Non-Operating (tape)
– 40 ˚C to 45 ˚C (
∆
T<20 ˚C/h)
(– 40 ˚F to 113 ˚F (
∆
T<36 ˚F/h))
Humidity
Operating
20 to 80% RH, non-condensing
Maximum wet bulb temperature :
26 ˚C (78.8 ˚F)
Non-Operating (mech.) 5 to 95% RH (
∆
RH<30%/h)
Maximum wet bulb temperature :
45 ˚C (113 ˚F)
Non-Operating (tape)
20 to 80% RH (
∆
RH<30%/h)
Summary of Contents for SDX-250V
Page 18: ...18 Orientation 10 10 10 10 10 10 10 10 ...
Page 33: ......
Page 34: ......
Page 35: ......
Page 36: ...Printed on 100 recycled paper Printed in Japan Sony Corporation ...