4-34
SAL16105 (DT 3.5-5.6/16-105) (DT 16-105mm F3.5-5.6)
4-10. FOCUS BRUSH POSITION CHECK/ADJUSTMENT
Equipment
• Personal Computer
• Finished Inspection JIG (AC100 V only)
• Lens Adjustment Program (ActuatorChecker2)
• Adhesive bond (B-10)
1. Preparations
1)
Take the mount side of lens apart to the rear barrel assy and install the lens mount and the rear light shield barrel.
Fig.4-10-1
2)
Connected to equipment with checking lens. (Refer to Section 4-1-4.)
3)
Start up of “ActuatorChecker2.exe”.
4)
Click
[Set up]
, and perform the initial setting. (Refer to Section 4-1-5.)
Rear Light
Sheild Barrel
Lens Mount Block
Cinuber Ring,
Rear Barrel Assy
Zoom Rubber Ring