![Sony SAL-35F14G - 35mm f/1.4 Aspherical G Series Standard Zoom Lens Service Manual Download Page 49](http://html.mh-extra.com/html/sony/sal-35f14g-35mm-f-1-4-aspherical-g-series-standard-zoom-lens/sal-35f14g-35mm-f-1-4-aspherical-g-series-standard-zoom-lens_service-manual_394140049.webp)
4-10
SAL35F14G (1.4/35G) (35mm F1.4G)
Finished Inspection JIG
Lens
4-1-3. Connection of Finished Inspection JIG and Lens Adjustment Program
(ActuatorChecker.exe)
Note:
Confirm “4-1-2. Lens Adjustment Program (ActuatorChecker)” has been completed before this procedure is executed.
Equipment
• Personal Computer
• USB cord with connector
• Finished Inspection JIG
• Lens Adjustment Program (ActuatorChecker.exe)
1.
Connect equipment and checking lens as shown Fig.4-1-20.
Fig.4-1-20
2.
Turn on the finished inspection JIG.
3.
Turn on the personal computer.
4.
Start up “ActuatorChecker.exe” from an arbitrary folder, conform that start up program normally.
Note:
Turn off the finished inspection jig after use.