9
4-3.
AMP CHECK MODE
Procedure:
1. Push back
[ ]
button to turn the power OFF.
2. Connect the lead wire to TP1 and TP2 on the KEY board.
3. Push
[ ]
button to power ON.
4. Let the lead wire connected TP1 and TP2.
5. Fluorescent indicator tube display “AMP CHK 500”, and enter the amp check mode.
6. The check step advances in order as TP1 and TP2 are shorted.
*1 The step 12 is the AUTO POWER ON/OFF check.
*2 The step 12 is automatically turned the power OFF in one second, ON when a signal is entered to TV input, and OFF when a signal
input stops.
*3 After the step 12 finished, return the parameters to default values, then turn the power OFF.
7. To release the test mode, push back
[ ]
button.
• Checking Location
– KEY Board (Conductor Side) –
AMP CHK 500
AMP CHK 1
AMP CHK 2
AMP CHK 3
AMP CHK 4
AMP CHK 5
AMP CHK 6
AMP CHK 7
AMP CHK 8
AMP CHK 9
AMP CHK 10
AMP CHK 11
AMP CHK 12
STEP
0
1
2
3
4
5
6
7
8
9
10
11
12
INPUT
VIDEO
VIDEO
VIDEO
VIDEO
VIDEO
VIDEO
AUX
AUX
5.1
5.1
5.1
5.1
TV
SW MODE
1
OFF
OFF
OFF
1
2
1
1
1
1
1
1
1
SUR MODE
PRO LOGIC
OFF
PRO LOGIC
GAME
OFF
OFF
PRO LOGIC
PRO LOGIC
–
–
–
–
PRO LOGIC
BASS
0
0
0
0
0
0
0
0
0
0
–5
+5
0
TREBLE
0
0
0
0
0
0
0
0
0
0
–5
+5
0
VOL
MIN
MAX
MAX
MAX
MAX
MAX
MIN
MAX
MAX
MIN
MAX
MAX
MAX
*
S505
S506
S502
TP3 TP2
TP4
TP1
S504
S503
S501
U
U
U
www.freeservicemanuals.info
05/28/2012
World of Free Manuals