![Sony PMC-MD55 - Md Boombox Service Manual Download Page 131](http://html.mh-extra.com/html/sony/pmc-md55-md-boombox/pmc-md55-md-boombox_service-manual_412199131.webp)
– 22 –
2. PRECAUTIONS FOR CHECKING LASER DIODE
EMISSION
To check the emission of the laser diode during adjustments, never
view directly from the top as this may lose your eye-sight.
3. PRECAUTIONS FOR USE OF OPTICAL
PICK-UP (KMS-260A)
As the laser diode in the optical pick-up is easily damaged by static
electricity, solder the laser tap of the flexible board when using it.
Before disconnecting the connector, desolder first. Before con-
necting the connector, be careful not to remove the solder. Also
take adequate measures to prevent damage by static electricity.
Handle the flexible board with care as it breaks easily.
Optical pick-up flexible board
4. PRECAUTIONS FOR ADJUSTMENTS
1. When replacing the following parts, perform the adjustments
and checks with
¬
in the order shown in the following table.
pick-up
flexible board
laser tap
Optical
Pick-up
BD Board
IC101, IC121
D101
IC171
1. Recording of IOP
information
(Value on the
optical pick-up
label)
2. Temperature
compensation
offset adjustment
3. Laser power
adjustment
4. EF balance
adjustment
5. Focus bias
adjustment
6. Error rate check
IC192
¬
¬
G
G
G
¬
G
¬
¬
¬
¬
G
¬
¬
G
¬
G
¬
¬
G
¬
G
¬
¬
G
2. Set the test mode when performing adjustments.
After completing the adjustments, release the test mode.
3. Perform the adjustments to be needed in the order shown.
4. Use the following tools and measuring devices.
• Check Disc (MD) TDYS-1
(Part No. 4-963-646-01)
• Test Disc (MDW-74/AU-1) (Part No. 8-892-341-41)
• Laser power meter LPM-8001 (Part No. J-2501-046-A)
or MD Laser power meter 8010S (Part No. J-2501-145-A)
• Oscilloscope (Measure after performing CAL of prove)
• Digital voltmeter
• Thermometer
• Jig for checking BD board waveform
(Part No. : J-2501-149-A)
5. When observing several signals on the oscilloscope, etc.,
make sure that VC and ground do not connect inside the oscil-
loscope.
(VC and ground will become short-circuited)
6. Using the above jig enables the waveform to be checked with-
out the need to solder.
(Refer to Servicing Notes on page 4)
7. As the disc used will affect the adjustment results, make sure
that no dusts nor fingerprints are attached to it.
Laser power meter
When performing laser power checks and adjustment (electrical
adjustment), use of the new MD laser power meter 8010S (Part
No. J-2501-145-A) instead of the conventional laser power meter
is convenient.
It sharply reduces the time and trouble to set the laser power meter
sensor onto the objective lens of optical pick-up.
5. CREATING CONTINUOUSLY-RECORDED DISC
* This disc is used in focus bias adjustment and error rate check.
The following describes how to create a continuous recording
disc.
1. Insert a disc (blank disc) commercially available.
2. Turn the JOG dial and display “CREC MODE”.
3. Press the
[YES, ENTER]
button again to display “CREC MID”.
Display “CREC (0300)” and start to recording.
4. Complete recording within 5 minutes.
5. Press the
[NO, CANCEL]
button and stop recording .
6. Press the
[MD EJECT ]
button and remove the disc.
The above has been how to create a continuous recorded data for
the focus bias adjustment/check and MO error rate check.
Note :
• Be careful not to apply vibration during continuous recording.
Z
¬
¬
G
G
G
Summary of Contents for PMC-MD55 - Md Boombox
Page 6: ... 6 SECTION 2 GENERAL This section is extracted from instruction manual ...
Page 7: ... 7 ...
Page 8: ... 8 ...
Page 39: ......
Page 42: ......
Page 43: ......
Page 45: ......
Page 49: ......
Page 52: ......
Page 53: ......
Page 55: ......
Page 57: ......
Page 59: ......
Page 115: ... 6 SECTION 2 GENERAL This section is extracted from instruction manual ...
Page 116: ... 7 ...
Page 117: ... 8 ...
Page 148: ......
Page 151: ......
Page 152: ......
Page 154: ......
Page 158: ......
Page 161: ......
Page 162: ......
Page 164: ......
Page 166: ......
Page 168: ......