22
SECTION 4
TEST MODE
Function name
x
button
7
button
.
or
>
button
POWER button
*
Function
Cancel or move to top hierarchy
Set
Select
Set submenu
4-1. PRECAUTIONS FOR USE OF TEST MODE
• As loading related operations will be performed regardless of the test mode operations being performed, be sure to check that the disc
is stopped before setting and removing it.
Even if the
A
button is pressed while the disc is rotating during continuous playback, continuous recording, etc., the disc will not stop
rotating.
Therefore, it will be ejected while rotating.
Be sure to press the
A
button after pressing the POWER“X2” button and the rotation of disc is stopped.
4-1-1. Recording laser emission mode and operating buttons
• Continuous recording mode (CREC 1MODE)
• Laser power check mode (LDPWR CHECK)
• Laser power adjustment mode (LDPWR ADJUS)
• Iop check (Iop Compare)
• Iop value nonvolatile writing (Iop NV Save)
• Traverse (MO) check (EF MO CHECK)
• Traverse (MO) adjustment (EF MO ADJUS)
• When pressing the
z
REC button.
4-2. SETTING THE TEST MODE
Procedure :
While pressing the
.
button and
x
button, connect the power plug to an outlet, and release the
.
button and
x
button.
When the test mode is set, “[Check]” will be displayed. Press the
.
or
>
button switches between the following three
groups; ···
y
Check
y
Service
y
Develop
y
···.
NOTE:
Do not use the test mode in the [Develop] group.
If used, the unit may not operate normally.
If the [Develop] group is set accidentally, press the
x
button immediately to exit the [Develop] group.
4-3. EXITING THE TEST MODE
Press the POWER“X2” button. The disc is ejected when loaded, and “Standby” display blinks, and the STANDBY state is set.
4-4. BASIC OPERATIONS OF THE TEST MODE
All operations are performed using the
.
or
>
button,
7
button, and
x
button.
The functions of these buttons are as follows.
*
NOTE:
It dosen’t work in the ease of “X2” mode.