– 13 –
3. Hereinafter, each time
> N
key is pressed, the reference
information display changes as follows:
4-6-2. Self-diagnostic mode
1. Set the TEST MODE.
2. With all the LCD display segments blinking on the set, press
DISPLAY key and the Self-diagnostic mode is entered.
• Press
.
key to go back to the previous display.
1st022
888
History code
Error display code
888
1st0
XX
888
1st100
888
1st200
888
N 0
XX
888
N 100
888
N 200
888
N-10
XX
888
N-1100
888
N-1200
888
N-20
XX
888
N-2100
888
N-2200
888
R 0000
(Turn back)
• Contents of the history codes
History code number
Contents
1st
0
The first error that occurred.
1st
1
Displays 00.
1st
2
N
0
The last error that occurred.
N
1
Displays 00.
N
2
N-1
0
The first error from the last one.
N-1
1
Displays 00.
N-1
2
N-2
0
The second error from the last one.
N-2
1
Displays 00.
N-2
2
REC
Total recording time (0000 is displayed
for MZ-E90.)
• Description of the error display codes
Contents of fault
Display code
Meaning of code
Description
No error
00
No error
01
Access target address illegally specified
An attempt to access an abnormal address.
Servo system error
02
HIGH TEMP
HIGH TEMP
03
FOCUS ERROR
Focus off-center.
04
SPINDLE ERROR
Abnormal rotation of disc
11
AUDIO error
12
13
21
INIT LOWBATT
Abnormal voltage during initialization
Power system error
22
LOWBATT
Instantaneous interruption detected.
23
LOWBATT NI
Instantaneous interruption detected (NiMH).
24
LOWBATT AM
Instantaneous interruption detected (AM).
4-6-3. Clearing the error display code
After servicing, reset the error display code.
1. Set the TEST MODE. (See page 11)
2. To reset the error display code, press
X
key on the remote
control when the code is displayed.