3-4-3.
Channel Setting
• The Channel menu enables selection of the channel (R-ch or G-ch or B-ch) to execute Record of RPN pixel on, in
the manual registration of RPN.
• When the RPN cursor (indicating location of an RPN pixel to register) is moved to an already-registered RPN
correction point by the Cursor Next or Cursor Prev operation, the correction mode selected for the RPN point is
displayed automatically.
3-4-4.
Cursor Setting
• The Cursor menu enables turning On or Off the crosshair cursor display indicating the RPN correction position in
the manual registration of RPN.
• When the Cursor menu is turned On, the crosshair cursor indicating the RPN correction position is displayed
superimposed on the video signal.
• Signal of the pixel located at the center of the crosshair cursor is replaced by black.
• The Cursor setting is always turned Off when the power is turned On.
3-4-5.
Cursor H Position Setting
• The Cursor H Position menu enables the user to change the horizontal position of the RPN point within the effective
period of video signal in the manual registration of RPN.
• When the RPN cursor (indicating the location of a RPN pixel to register) is moved to an already-registered RPN
correction point by the Cursor Next or Cursor Prev operation, the display automatically switches to the numeric
value of the horizontal position of the RPN point.
3-4-6.
Cursor V Position Setting
• The Cursor V Position menu enables the user to change the vertical position of the RPN point within the effective
period of video signal in the manual registration of RPN.
• When the RPN cursor (indicating the location of a RPN pixel to register) is moved to an already-registered RPN
correction point by the Cursor Next or Cursor Prev operation, the display automatically switches to the numeric
value of the vertical position of the RPN point.
3-4-7.
Operating Cursor Next
• The Cursor Next menu enables the user to move the RPN cursor position to the next already-registered RPN
correction point after the present position in the ascending order of the addresses during the manual registration of
RPN.
Note
If multiple RPN positions have the same address in the ascending order of the Cursor V Position, the RPN cursor
moves in the ascending order of the Cursor H Position.
MCC-3000MT