5-20
Fig. 5-1-14.
Fig. 5-1-15.
4. Bright Adjustment (PK-44 board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
Playback
Signal
Alignment disk (TFD2-1(+) or TFD2-
2(–)):
Stair step signal of 10 steps (MVC-
006T.JPG)
Measurement Point
Pin
9
of CN802 (VG)
External trigger: Pin
8
of CN802
(COM)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
30
Specified Value
A = 2.05 ± 0.05V
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 02, and set data: 01.
3)
Select page: 3, address: 19, and set data: 08.
4)
Select page: F, address: 30, change the data and set the voltage
(A) between the pedestal and white level to the specified value.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 3, address: 02, and set data: 00.
7)
Select page: 3, address: 19, and set data: 00.
8)
Select page: 0, address: 01, and set data: 00.
5. Contrast Adjustment (PK-44 board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
Playback
Signal
Alignment disk (TFD2-1(+) or TFD2-
2(–)):
Stair step signal of 10 steps (MVC-
006T.JPG)
Measurement Point
Pin
9
of CN802 (VG)
External trigger: Pin
8
of CN802
(COM)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
34
Specified Value
A = 3.52 ± 0.07V
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 02, and set data: 01.
3)
Select page: F, address: 34, change the data and set the voltage
(A) between the 0 IRE (pedestal) and 100 IRE to the specified
value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: 3, address: 02, and set data: 00.
6)
Select page: 0, address: 01, and set data: 00.
Pedestal
A
2H
White
0 IRE
2H
100 IRE
A
Summary of Contents for Mavica MVC-FD81
Page 8: ...1 1 MVC FD81 SECTION 1 GENERAL This section is extracted from instruction manual ...
Page 9: ...1 2 ...
Page 10: ...1 3 ...
Page 11: ...1 4 ...
Page 12: ...1 5 ...
Page 13: ...1 6 ...
Page 14: ...1 7 ...
Page 15: ...1 8 ...
Page 16: ...1 9 ...
Page 17: ...1 10E ...
Page 24: ...MVC FD81 SECTION 3 BLOCK DIAGRAMS 3 1 OVERALL BLOCK DIAGRAM 3 1 3 2 3 3 MVC FD81 ...
Page 28: ...MVC FD81 3 5 POWER BLOCK DIAGRAM 3 13 3 14 3 15E ...