101
R
Communication error between MASM-1 and
MAS-A100
Is MAS-A100 controlled by
MASM-1 only?
Is the MAS-A100 LED lamp
lit?
No
No
Occurs when controlling the same MAS-A100
via multiple applications.
Wait a while, and then try again.
Turn the MAS-A100 off and then on again.
Contact your local Sony dealer.
I
IP communication trouble
Are MAS-A100 units and PC
connected on the same subnet?
Is proxy use disabled?
Is SSL communication with
MAS-A100 disabled?
No
No
No
Connect the PC to the same subnet as the
MAS-A100 or enable communication via a
router.
(See “4.3 Network design” (page 23))
Disable the use of a proxy, and configure
communication with the MAS-A100.
(See “4.3 Network design” (page 23))
The MASM-1 does not support SSL.
Disable the use of SSL on the MAS-A100.
(See “4.3 Network design” (page 23))
Contact your local Sony dealer.