– 5 –
KV-ES29M80/ES29M81/ES29M90
RM-916
2.
DISPLAY OF STANDBY/TIMER LIGHT FLASH COUNT
Lamp ON 0.3 sec.
Lamp OFF 3 sec.
Lamp OFF 0.3 sec.
2 times
3 times
4 times
5 times
6 times
7 times
Diagnostic Item
Flash Count*
+B overcurrent
2 times
+B overvoltage
3 times
V deflection stop
4 times
White balance failure
5 times
High voltage protector
6 times
Audio Protection
7 times
* One flash count is not used for self-diagnostic.
3.
STOPPING THE STANDBY/TIMER FLASH
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY/TIMER lamp
from flashing.