![Sony KV-28FQ75U Service Manual Download Page 22](http://html.mh-extra.com/html/sony/kv-28fq75u/kv-28fq75u_service-manual_1330625022.webp)
22
GREEN
BLUE
RED
(1) Screen centre convergence [Static convergence]
1.
Input a dot pattern signal from the pattern generator.
2.
Normalize the picture setting.
3.
[Moving vertically], adjust the V.STAT magnet so that the
vertical red, green and blue dots coincide at the centre of the
screen.
3-2. Convergence
By opening or closing the V.STAT magnet, the red green and blue
dots move in the direction indicated below.
Note:
Do not adjust the H.STAT by rotating the V.STAT
magnets as this can affect the focus setting.
B
G
R
B
G
R
Fig.3-6
Purity magnets
Align pips on
each magnet
Fig.3-5
Align both Purity magnets
to the vertical position
Center dot
R
G
B
R
G
B
C Board
RV5375 (H STAT)
H STAT Convergence
(on mount side)
H STAT
convergence
control
V.STAT Vertical Static Magnet
Purity control magnets
Purity control corrects
this area
Disk magnets or
rotatable disk
magnets correct
these areas (a-d)
Deflection yoke positioning
corrects these areas
a
c
d
b
Disk Magnets
Fig.3-4
DY
DY Wedges