– 21 –
KP-FX432M31/FX432M91/FX532M91
RM-998
RM-998
RM-998
3-9. SERVICE LIST
Category
Item
Function
Standard Data
Device Name
No.
Name
(Slave Address)
OSD
0
OSV
OSD V Position
32
CXP961F064(60H)
1
OSH
OSD H Position
13
2
FW1
OSD ODD/EVEN Field Window Setup #1
7
3
FW2
OSD ODD/EVEN Field Window Setup #2
20
4
VOF
OSD V Position (Offset)
*1
OSD: Standard Data *1
Item
Standard Data
No.
Name
OSD V OFFSET
HD50
HD60
VCOMP
VCOMP60
VCOMP100
VCOMP120
4
VOF
32
32
32
32
32
32
OSD: Standard Data *1
Item
Standard Data
No.
Name
OSD V OFFSET
FULL50
FULL60
FULL100
FULL120
4
VOF
32
32
16
16
Note
•
: The data value of each mode. Other are set up by each mode.
•
: Shaded items are fixed data.
•
: Though data value is indicated on the screen, it is not used.
•
Standard data listed on the Adjustment Item Table are reference valies, therefore it may be different for each model and each mode.
•
Note for Different Data :
Those are the standard data values written on the microprocessor. Therefore , the data values of the modes and stored respectively in the memory.
In case of a device replacement, adjustment by rewriting the data value is necessary for some items.