![Sony KP-ES43HK1 Service Manual Download Page 71](http://html.mh-extra.com/html/sony/kp-es43hk1/kp-es43hk1_service-manual_414899071.webp)
– 71 –
KP- ES43HK1/ME1/MN1/SN1, ES48HK1/ME1/MN1/SN1,
ES53HK1/ME1/MN1/SN1, ES61HK1/ME1/MN1/SN1
K
RM-961
10.INDEX 60 Hz (NTSC) Mode
1) Enter the NTSC monoscope signal, and set in the service
mode.
2) Press “PROGR INDEX” button on the commander to set the
INDEX mode.
3) Confirm and set the following data.
Condition :
Category
Item
Data
GEO
00
VSZ
01
VPS
02
VLN
03
SCO
04
HSZ
05
HPS
07
PAP
08
UPN
09
LPN
0A
TRZ
0B
AGL
07
0C
BOW
07
15
VSC
22
MID
00
HPH
6C
01
VPH
2D
4) Select the category “GEO” and the item “05 HPS” to adjust
the horizontal position, and select the item “01 VPS” to ad-
just the vertical position.
9. TWIN 60 Hz (NTSC) Mode
1) Enter the NTSC monoscope signal, and set in the service
mode.
2) Press “
(TWIN)” button on the commander to set the
TWIN mode.
3) Confirm and set the following data.
Condition :
Category
Item
Data
GEO
00
VSZ
01
VPS
02
VLN
03
SCO
04
HSZ
05
HPS
07
PAP
08
UPN
09
LPN
0A
TRZ
0B
AGL
07
0C
BOW
07
15
VSC
22
MID
00
HPH
6F
01
VPH
2E
11
TMP
01
12
TSP
00
4) Select the category “GEO” and the item “05 HPS”, and ad-
just the horizontal position.
Same as
DRC1250
60 Hz (NTSC)
mode
H1
H2
H1 – H2 =
±
0.1 sq.
H1
H2
V2
V1
V1 – V2 =
±
0.1 sq.
H1 – H2 =
±
0.1 sq.
Same as
DRC1250
60 Hz (NTSC)
mode
5) Press “
(MUTE)”+“
-
” buttons on the commander to
write the data to the NVM.
5) Press “
(MUTE)”+“
-
” buttons on the commander to
write the data to the NVM.