Safety Notes
ITC2
CHASSIS
R402/ R407/ R422/ R435/ R452/ R457/ R472/ R488
1-5. How to Find a Good Earth Ground
1) A cold-water pipe is a guaranteed earth ground; the cover-plate retaining
screw on most AC outlet boxes is also at earth ground.
2) If the retaining screw is to be used as your earth ground verify that it is at
1-7. Handling the FLEXIBLE FLAT CABLE (FFC)
When you insert / pull out FFC, please grasp a reinforcement board and main body of
FFC.
2) If the retaining screw is to be used as your earth ground, verify that it is at
ground by measuring the resistance between it and a cold-water pipe with an
ohmmeter. The reading should be zero ohms.
3) If a cold-water pipe is not accessible, connect a 60- to 100-watt trouble-
light (not a neon lamp) between the hot side of the receptacle and the
retaining screw Try both slots if necessary to locate the hot side on the line;
retaining screw. Try both slots, if necessary, to locate the hot side on the line;
the lamp should light at normal brilliance if the screw is at ground potential
(see Figure 3).
1-6. Lead Free Information
Figure 3. Checking for earth ground.
The circuit boards used in these models have been processed using Lead
Free Solder. The boards are identified by the LF logo located close to the
board designation.
Main Board
Main Board
Figure 4: LF Logo
Figure 5: LF logo on circuit board
Th
i i
f th
b
d
i
i l
ti
It i
t
l
7
The servicing of these boards requires special precautions. It is strongly
recommended to use Lead Free Solder material in order to guarantee optimal
quality of new solder joints.
< Insertion>
<Pull out>