- 5 -
SE1A
RM-ED009
CONNECTORS
21 Pin Connector (SCART)
_
_ Red input
0.7 +/- 3dB, 75 ohms, positive
_
(S signal Chroma
Connected
Not Connected (open) * at 20Hz - 20kHz
Pin No
1
2
Signal
Signal level
1
Audio output B
(right)
Standard level : 0.5V rms
Output impedence : Less than 1kohm*
2
Audio input B
(right)
Standard level : 0.5V rms
Output impedence : More than 10kohm*
3
Audio output A
(left)
Standard level : 0.5V rms
Output impedence : Less than 1kohm*
4
Ground (audio)
5
Ground (blue)
6
Audio input A
(left)
Standard level : 0.5V rms
Output impedence : More than 10kohm*
7
Blue input
0.7 +/- 3dB, 75 ohms positive
8
Function select
(AV control)
High state (9.5-12V) : Part mode
Low state (0-2V) : TV mode
Input impedence : More than 10K ohms
Input capacitance : Less than 2nF
9
Ground (green)
10
AVlink
11
Green
Green signal : 0.7 +/- 3dB, 75 ohms,
positive
12
Open
13
Ground (red)
14
Ground (blanking)
15
input)
0.3 +/- 3dB, 75 ohms, positive
16
Blanking input
(Ys signal)
High state (1-3V) Low state (0-0.4V)
Input impedence : 75 ohms
17
Ground (video
output)
18
Ground (video
input)
19
Video output
1V +/- 3dB, 75ohms, positive sync 0.3V
(-3+10dB)
20
Video input
1V +/- 3dB, 75ohms, positive sync 0.3V
(-3+10dB)
Video input
Y (S signal)
1V +/- 3dB, 75ohms, positive sync 0.3V
(-3+10dB)
21
Common ground
(plug, shield)
- -
- -
19
17
15
13
11
9
7
5
3
1
20
18
16
14
12
10
8
6
4
2
21
How to replace the fuse.
Open the fuse compartment with
a screwdriver blade and replace
the fuse.
FUSE
WARNING
(UK Models only)
The flexible mains lead is supplied connected to a
B.S. 1363
fused
plug having a fuse of
13 AMP
rating. Should the fuse need to be
replaced, use a
13AMP FUSE
approved by ASTA to
BS 1362
, ie one
that carries the
ASA
T
mark.
IF THE PLUG SUPPLIED WITH THIS APPLIANCE IS NOT SUIT-
ABLE FOR THE OUTLET SOCKETS IN YOUR HOME, IT SHOULD
BE CUT OFF AND AN APPROPRIATE PLUG FITTED. THE PLUG
SEVERED FROM THE MAINS LEAD MUST BE DESTROYED AS A
PLUG WITH BARED WIRES IS DANGEROUS IF ENGAGED IN A
LIVE SOCKET.
When an alternative type of plug is used, it should be fitted with a
13 AMP FUSE
, otherwise the circuit should be protected by a
13AMP FUSE
at the distribution board.
UK PLUG WARNING
Summary of Contents for KDL-32S2800
Page 9: ... 8 SE1A RM ED009 SECTION 2 DISASSEMBLY 2 2 STAND REMOVAL 2 1 REAR COVER REMOVAL ...
Page 10: ... 9 SE1A RM ED009 2 3 COVER UNDER REMOVAL 2 4 AC INLET REMOVAL ...
Page 11: ... 10 SE1A RM ED009 2 5 LOUD SPEAKER REMOVAL 2 6 H1 BOARD REMOVAL ...
Page 12: ... 11 SE1A RM ED009 2 7 BC BOARD REMOVAL ...
Page 13: ... 12 SE1A RM ED009 2 8 U1 BOARD REMOVAL 2 9 H3 BOARD REMOVAL ...
Page 14: ... 13 SE1A RM ED009 2 10 G1 BOARD REMOVAL 32 INCH 2 11 H4 BOARD REMOVAL ...
Page 15: ... 14 SE1A RM ED009 2 12 D1 and G3 BOARD REMOVAL ...
Page 16: ... 15 SE1A RM ED009 2 13 VESA ARM and LCD PANEL REMOVAL 32 INCH ...
Page 17: ... 16 SE1A RM ED009 2 14 VESA ARM and LCD PANEL REMOVAL 40 INCH ...