![Sony ixs-6600 Installation Manual Download Page 49](http://html.mh-extra.com/html/sony/ixs-6600/ixs-6600_installation-manual_400393049.webp)
1-41
IXS-6600/6700
6. SG-281 Board <IXS-6600/IXS-6700>
<LED>
D501 (A-2) : Main
+
+
+
+
+
12 V
Status indication of the
+
12 V power supply on the main
CPU.
Lights when the
+
12 V power on the main CPU is sup-
plied.
If this LED does not light, the fuse may have blown.
D502 (A-2) : Control
+
+
+
+
+
12 V
Status indication of the
+
12 V power supply on the control
CPU.
Lights when the
+
12 V power on the control CPU is
supplied.
If this LED does not light, the fuse may have blown.
D504 (A-3) :
+
+
+
+
+
3.3 V
+
3.3 V power supply status indication.
Lights when the
+
3.3 V power is supplied.
When the
+
12 V power supply is not supplied either to the
main or control CPU, this LED does not light.
D505 (A-2) :
+
+
+
+
+
5 V
+
5 V power supply status indication.
Lights when
+
5 V power is supplied.
When the
+
12 V power supply is not supplied either to the
main or control CPU, this LED does not light.
D501
D502
D505
D504
1
2
3
4
5
6
A
B
C
D
1-11. Setting the IP Address
Setting the network connection (IP address)
m
.
If network setting is performed on the Main CPU board,
its values are automatically set in the backup CPU (CA-
65) board.
.
Do not use the IP address of IXS-6700/IXS-6600 with its
factory default value “192.168.0.135” when two or more
units of the IXS-6700/IXS-6600 are used on the same
network.
Be sure to set an IP address other than that.
.
Do not set the IP address of IXS-6700/IXS-6600 to
“192.168.1.xxx” or “172.16.2.xxx”. Be sure to set an IP
address other than that. (xxx indicates a desired value
from 0 to 255.)
The IP address of IXS-6700/IXS-6600 has the following
two types.
.
Desired IP address
.
10. [Group ID] .6. [Unit ID]
(The first byte and the third byte are fixed.)
Group ID can be set within the range between 129 and
191.
Which IP address is to be set can be selected with switch
S1202-4.
S1202-4
IP address
ON
Desired IP address
OFF
10. [Group ID] .6. [Unit ID] (Factory default
setting : 10.129.6.0)
.
Set the Group ID in the following procedure.
.
Set the Unit ID with S801.
Group ID and a desired IP address can be set on the same
PC screen.
The settings can be set with the included GUI software
BZR-25 for network setting or with the following setting
procedure.
For details about installing BZR-25, see “2-4-2. Installing
BZR-20/BZR-25”. For details about using BZR-25, see the
BZR-25 online help.
To activate the BZR-25 settings, the switch S1204-4 must
be turned to ON.