12
MZ-RH10
OUTLINE
Operation in the test mode is performed with the set. A key having
no particular description in the text, indicates a set key. Also, For
the LCD display, the LCD on the remote commander is shown.
(The running system is displayed in set EL instead of the disk mark)
Remote commander LCD display
Set EL display
(all off)
off
(all lit)
x
(inner rotation, outer lit)
B
(inner lit, outer off)
.
(inner off, outer lit)
>
1. OPERATION IN SETTING THE TEST MODE
•
When the test mode becomes active, first the Display Check
mode is selected.
•
Other mode can be selected from the Display Check mode.
•
When the test mode is set, the LCD repeats the following
display.
•
When the
x
key is pressed and hold down, the display at that
time is held so that display can be checked.
Display check mode:
SECTION 4
TEST MODE
Display Check Mode
Version display
→
All lit
→
All off
→
Version display...
[VOL +]
key
x
key
x
key
N
/ENT
key
x
key
>
key
x
key
[REC/T MARK]
key
[SEARCH/MENU]
key
[VOL --]
key
x
key
Open the lid
Manual Mode
Sound Skip Check Result
Display Mode (Play)
Self-Diagnosis Result Display Mode
Sound Skip Check Result
Display Mode (REC)
Key Check Mode
Overall Adjustment Mode
Key Count Mode
[SEARCH/MENU]
key
(press a few
seconds)
Remote commander
[DISPLAY]
key
(press a few seconds)
(Not used in servicing)
000
Manual
000
1 0000
000
P00r00
000
p00R00
000
MENU 000
110
10
000
AdjF**
002
V1.000
888
002
V1.000
F
1SHUFPGM SOUND
V-SUR
8
All lit
Remote commander LCD display
All off
Microcomputer
version display
2. CONFIGURATION OF THE TEST MODE
Flow of the test mode:
All lit
Set EL display
All off
Microcomputer
version display
002[80**]
Ver 1.000
BEr******