![Sony HCD-RV777D Service Manual Download Page 9](http://html.mh-extra.com/html/sony/hcd-rv777d/hcd-rv777d_service-manual_416430009.webp)
9
HCD-RV777D/RV888D/RV999D
1-6. DECISION TO PASS OR FAIL OF THE OPTICAL PICK-UP BLOCK
1-5. NOTE OF TRANSFORMER
oscilloscope
+
DMB07 board
CN901 pin 1
–
CN901 pin 3
CD : 1.05
±
0.2 Vp-p
VOLT/DIV : 200 mV
TIME/DIV : 500 nS
DVD : 1.09
±
0.2 Vp-p
RF signal waveform
– DMB07 BOARD (SIDE A) –
CN901
1
7
Connection:
Procedure:
1. Connect an oscilloscope to test point
1
pin and
3
pin of CN901
2. Turn the power on.
3. Put the disc (LUV-P01) (Part No.: 4-999-032-01) (CD) in to
4. Confirm that oscilloscope waveform is clear and check RF
signal level is correct or not.
5. Put the disc (TDV-520CSO) (Part No.: J-2501-236-A) (DVD)
6. Perform Comfirmation in the same manner as step 4.
Note:
A clear RF signal waveform means that the shape “
◊
” can be clearly
distinguished at the center of the waveform.
Checking Location:
transformer
(T901)
more than 3mm
power cord
Pull the power cord in the direction of the arrow
A
with care to keep the cord from
contact with the transformer (T901).
Then fix the cord using two clips
indicated by the arrow
B
.
back panel
australian, saudi arabia
model only
SUB TRANS board
A
B
B
NOTE: Make sure that the power cord is distant
more than 3mm from the transformer (T901).
www. xiaoyu163. com
QQ 376315150
9
9
2
8
9
4
2
9
8
TEL 13942296513
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299