14
HCD-GP6V
[Cold Reset]
•
The cold reset clears all data including preset data stored in
the RAM to initial conditions. Execute this mode when re-
turning the set to the customer.
Procedure:
1. Press the
"
/
1
button to turn off the main power.
2. While depressing the
x
button, press the
"
/
1
button.
3. The fluorescent indicator tube does not display any message
and the set is reset.
[Fluorescent Indicator Tube Test Mode]
•
Fluorescent segments are tested when this test is activated.
Procedure:
1. Extract an AC plug.
2. While depressing the CD
u
button, insert an AC plug.
3. All segments of the fluorescent indicator tube turn on.
4. CD test mode is activated.
5. To exit from this mode, press the
"
/
1
button or disconnect the
power cord.
[Version Display Mode]
•
The model and the version are displayed.
Procedure:
1. Press the
"
/
1
button to turn the set on.
2. To enter the test mode, press two buttons
x
and
"
/
1
simulta-
neously for more than five seconds. The model and the ver-
sion are displayed.
[AMP Test]
•
This mode is used to check the function of the amplifier.
Procedure:
1. Extract an AC plug.
2. While depressing the
[MD]
button, insert an AC plug to enter
the AMP test mode. The message “AMP TEST” is displayed.
3. The message “Volume MAX” is displayed, when pressing the
[]
button. The message “Volume MIN” is displayed,
when pressing the
[VOLUME --]
button.
4. Each time pressing the
[PLAY MODE/TUNING MODE]
button,
the message “EQ MAX”, “EQ MIN” or “EQ FLAT” is dis-
played in this order.
5. To release from this mode, disconnect the AC plug and turn
the power off.
[AM Channel Step 9 kHz/10kHz Selection Mode]
•
Either the 9 kHz step or 10 kHz step can be selected for the
AM channel step.
Procedure:
1. Set the function to AM.
2. While depressing the
[TUNER/BAND]
button, press the
"
/
1
button.
3. The channel step is changed over.
[TC Test Mode]
Procedure:
1. Extract an AC plug.
2. While depressing the TAPE
nN
button, insert an AC plug.
3. The message “TC TEST” is displayed and TC test mode is
activated.
•
Zero Return
1. Press the +
> M
or –
.m
button.
2. The tape is rewound to the counter zero position.
•
Automatic record/playback test
1. Press the
[REC START/REC PAUSE]
button.
2. The message “MD” is displayed and AUX input is selected.
3. The tape is rewound to the counter zero position and record-
ing is started automatically.
4. When the
x
button is pressed, the tape is rewound to the
recording stated point and the set starts playback.
5. To exit from this mode, press the
"
/
1
button or disconnect the
power cord.
SECTION 4
TEST MODE