33
HCD-CL5MD
Note:
Clear RF signal waveform means that the shape “
◊
” can be
clearly distinguished at the center of the waveform.
RF signal waveform
E-F Balance (1 Track jump) Check
Procedure:
1. Connect oscilloscope to TP (TEO) and TP (DVC) board.
2. Turned Power switch on.
3. Load a disc (YEDS-18) and playback the number five track.
4. Press the
u
button. (Becomes the 1track jump mode.)
5. Confirm that the level B and A (DC voltage) on the oscilloscope
waveform.
1 track jump waveform
Specification level:
x
100=less than ±22%
6. After check, remove the lead wire connected in step 1.
RF PLL Free-run Frequency
Procedure :
1. Connect frequency counter to test point (XPCK) with lead wire.
2. Turned Power switch on.
3.
Put the disc (YEDS-18) in to play the number five track.
Confirm that reading on frequency counter is 4.3218MHz.
oscilloscope
BD (CD) board
TP (TEO)
TP (DVC)
+
–
A
B
+
–
frequency counter
BD (CD) board
TP (XPCK)
Adjustment Location :
[ BD (CD) BOARD ] — SIDE B —
IC103
IC101
TP
(RFDC)
TP
(CE)
TP
(RFAC)
TP
(XPCK)
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 1.1
±
0.3Vp-p
0V
Center of
waveform
B
Symmetry
A (DC voltage)
level=1.3
±
0.6Vp-p