26
HCD-C700/C900
[0]
Reset SLED TILT
Reset the Sled and Tilt to initial position.
[1]
LD
Turn ON/OFF the laser.
[2]
SP
Turn ON/OFF the spindle.
[3]
Focus
Search the focus and turn on the focus.
[4]
TRK
Turn ON/OFF the tracking servo.
[5]
Sled
Turn ON/OFF the sled servo.
[6]
CLVA
Turn ON/OFF normal servo of spindle
servo.
[7]
FCS. Srch
Apply same voltage as that of focus
search to the focus drive to check the
focus drive system.
→
Sled FWD
Move the sled outward. Perform this
operation with the tracking servo turned
off.
←
Sled REV
Move the sled inward. Perform this
operation with the tracking servo turned
off.
↑
Tilt UP
Move the tilt upward.
↓
Tilt DOWN
Move the tilt downward.
The following menus are normally not used.
3.
Track/Layer Jump
4.
Manual Adjustment
5.
Auto Adjustment
The persons who do not know well about these menus should not
use them.
6. Memory Check
EEPROM Data1
-– DL –-
CD LCD
SL
L0
L1
Focus Gain
xx xx
xx
xx
xx
TRK. Gain
xx xx
xx
xx
xx
FCS Balance
xx xx
xx
xx
xx
Focus Bias
xx xx
xx
xx
xx
TRV. Offset
xx xx
xx
xx
xx
L. F. Offset
xx xx
xx
xx
xx
EQ Boost
xx xx
xx
xx
xx
Mirror Time
xx xx
xx
xx
xx
_DOWN: Next Data
CLEAR: Default Set page.1/2
EEPROM Data1
-– DL –-
CD LCD
SL
L0
L1
RF Jitter
xx --
xx
xx
xx
RF Level
xx --
xx
--
--
FE Level
xx --
xx
--
--
FE Balance
xx --
xx
--
--
TRV. Level
xx --
xx
--
--
Analog FRSW
xx xx
xx
xx
xx
PLL DacGain
xx xx
xx
xx
xx
_
UP : Prev Data
CLEAR: Default Set page.2/2
This screen displays current servo adjusted data stored in the
EEPROM. Though adjusted data can be initialized with the
[CLEAR]
key, they cannot be restored after initialization.
So, before clearing, make a note of the adjusted data.
For reference, the drive has been designed so that the gain center
value is 20 and offset value is 80. Other values will be in a range of
10 to 80. If extreme value such as 00 or FF is set, adjustment will be
faulty. In such a case, check for disc scratch or cable disconnection,
then perform adjustment again.
7. Sacd Water Mark
4-12. MECHA AGING
### Aging Test MENU ###
Operation Menu
1.Changer Open/Close Test
2.Changer Exchange Test
_
Exit: RETURN
On the Test Mode Menu Screen, selecting
[3]
executes the aging of
the mechanism. Start aging with PLAY. During aging, the repeat
cycle is displayed. Aging can be aborted at any time by pressing the
x
key. After the operation is stopped, press the
[RETURN]
key
again to return to the Test Mode Menu.