1-2
DCR-PC53E/PC55/PC55E
ENGLISH
JAPANESE
ENGLISH
JAPANESE
2.
POWER SUPPLY DURING REPAIRS
In this unit, about 10 seconds after power is supplied to the battery terminal using the regulated power supply (8.4V), the power is shut off so
that the unit cannot operate.
This following two methods are available to prevent this. Take note of which to use during repairs.
Method 1.
Use the AC power adaptor.
Method 2.
Connect the servicing remote commander RM-95 (J-6082-053-B) to the LANC jack, and set the commander switch to the “ADJ” side.
3.
TO TAKE OUT A CASSETTE WHEN NOT EJECT (FORCE EJECT)
1
Remove the top cabinet assembly.
2
Remove the cabinet (R) assembly.
3
Remove the front panel assembly.
4
Remove the FB-223 board.
5
Remove the cabinet (L) assembly.
6
Disconnect CN1002 (29P, 0.3mm) of VC-379 board.
7
4.5V from the DC power supply to the loading motor and unload with pressing the cassette compartment.
VC-379
VC-379 board
CN1002
Loading motor
DC power supply (+4.5Vdc)
Disconnect the flexible board
from CN1002 of VC-379 board.
Summary of Contents for Handycam DCR-PC53E
Page 2: ... 2 DCR PC53E PC55 PC55E SPECIFICATIONS ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 3: ... 3 DCR PC53E PC55 PC55E ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 5: ... 5 DCR PC53E PC55 PC55E ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 11: ...1 5 DCR PC53E PC55 PC55E SECTION 1 SERVICE NOTE ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 12: ...1 6 DCR PC53E PC55 PC55E ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 13: ...1 7 DCR PC53E PC55 PC55E ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 14: ...1 8E DCR PC53E PC55 PC55E ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 60: ...5 11 5 REPAIR PARTS LIST 5 REPAIR PARTS LIST DCR PC53E PC55 PC55E J MODEL ...