— 16 —
KV-36FS100/36FS200/38FS200
SECTION 3: SAFETY RELATED ADJUSTMENTS
3-1.
X
R530, R531 CONFIRMATION METHOD
(HOLD-DOWN CONFIRMATION) AND
READJUSTMENTS
Always perform the following adjustments when replacing the following
components marked with a
Y
mark on the schematic diagram:
� ������
�� ���� ����
����� ����� ����� �����
������ ����� ����� �����
����� ����� ����� �����
����� ����
����� ����
���� �������� � �
���������� � �
3-1-1. PREPARATION BEFORE
CONFIRMATION
1. Using a Variac, apply AC input voltage: 120 +/- 2.0 VAC.
2. Turn the POWER switch ON.
3. Input a white signal and set the PICTURE and BRIGHT controls to
maximum.
4. Confirm that the voltage of more than 23.0 VDC appears between
TP85 and ground on the A Board.
3-1-2. HOLD-DOWN OPERATION
CONFIRMATION
1. Connect the current meter between Pin 11 of the FBT (T503) and the
PWB land where Pin 11 would normally attach. (See Figure 1).
2. Input a dot signal and set PICTURE and BRIGHTNESS to minimum:
IABL = 2175 + 100/ -325 µA.
3. Confirm the voltage of A Board TP91 is 135 ± 1.5 VDC.
4. Connect the digital voltmeter and the DC power supply to TP85 and
ground. (See Figure 1)
5. Increase the DC power voltage gradually until the picture blanks out.
6. Turn DC power source off immediately.
7. Read the digital voltmeter indication (standard = 27.24 + 0.0/ - 0.1
VDC).
8. Input a white signal and set PICTURE and BRIGHTNESS to
maximum: IABL = 2175 + 100/ -325 µA.
9. Repeat steps 4 to 7.
3-1-3. HOLD-DOWN READJUSTMENT
If the setting indicated in Step 2 of Hold-Down Operation Confirmation
cannot be met, readjustment should be performed by altering the
resistance value of R530, R531 component marked with
X
.
3mA DC range
+
-
+
-
A
+
-
FBT
TP85
T503
FBT
TP85
R531 R530
DC Power Supply
digital multimeter
ammeter
Figure 1
3-2. B+ VOLTAGE CONFIRMATION AND
ADJUSTMENTS
Always perform the following adjustments when replacing the following
components, which are marked with
Y
on the schematic diagram on the
GK Board:
GK BOARD:
IC600, PH602
1. Using a Variac, apply AC input voltage: 130 + 2.0/-0.0 VAC
2. Input a monoscope signal.
3. Set the PICTURE control and the BRIGHT control to
minimum.
4. Confirm the voltage on A Board between TP23 and ground is less
than 136.5 VDC.
5. If step 4 is not satisfied, replace R530 and R531 on A Board and
repeat the above steps.
Summary of Contents for FD Trinitron WEGA KV-36FS100
Page 32: ... 32 KV 36FS100 36FS200 38FS200 ...
Page 33: ... 33 KV 36FS100 36FS200 38FS200 A BOARD WAVEFORMS ...
Page 34: ... 34 KV 36FS100 36FS200 38FS200 ...
Page 35: ... 35 KV 36FS100 36FS200 38FS200 ...
Page 71: ......
Page 75: ...User Guide ...
Page 77: ......
Page 93: ......
Page 115: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 129: ......
Page 130: ......
Page 131: ......
Page 132: ......
Page 133: ...Sony Corporation Printed in U S A ...
Page 135: ...User Guide ...
Page 141: ......
Page 147: ......
Page 157: ......
Page 161: ......
Page 177: ......
Page 185: ......
Page 187: ......
Page 188: ......
Page 189: ......
Page 190: ......
Page 191: ......
Page 192: ......
Page 193: ......
Page 194: ......
Page 195: ......
Page 196: ......
Page 197: ...User Guide Sony Corporation Imprimé aux États unis ...
Page 199: ...Manual de instrucciones ...
Page 203: ...Manual de instrucciones ...
Page 205: ......
Page 221: ......
Page 245: ...Manual de instrucciones Corporación Sony Impreso en EE UU ...