— 16 —
KV-27FS100/27FS200/29FS100/
32FS100/32FS200/34FS100
3-1.
X
R530, R531 CONFIRMATION METHOD
(HOLD-DOWN CONFIRMATION) AND
READJUSTMENTS
Always perform the following adjustments when replacing the following
components marked with a
Y
mark on the schematic diagram:
A BOARD:
HV HOLD DOWN
R550, T503, T504, D519,
IC501, R533, D521, R532,
D520, C531, R529, R530,
R531, C532
R530, R531
Part Replaced (
)
Adjustment (
)
PREPARATION BEFORE CONFIRMATION
1. Using a Variac, apply AC input voltage: 120 +/- 2.0 VAC.
2. Turn the POWER switch ON.
3. Input a white signal and set the PICTURE and BRIGHT controls to
maximum.
4. Confi rm that the voltage of more than 23.0 VDC appears between
TP85 and ground on the A Board.
HOLD-DOWN OPERATION CONFIRMATION
1. Connect the current meter between Pin 11 of the FBT (T503) and the
PWB land where Pin 11 would normally attach. (See Figure 1).
2. Input a dot signal and set PICTURE and BRIGHTNESS to minimum:
IABL = 2175 + 100/ -325 µA.
3. Confi rm the voltage of A Board TP91 is 135 ± 1.5 VDC.
4. Connect the digital voltmeter and the DC power supply to TP85 and
ground. (See Figure 1 above).
5. Increase the DC power voltage gradually until the picture blanks out.
6. Turn DC power source off immediately.
7. Read the digital voltmeter indication (standard = 27.24 + 0.0/ - 0.1
VDC).
8. Input a white signal and set PICTURE and BRIGHTNESS to
maximum: IABL = 2175 + 100/ -325 µA.
9. Repeat steps 4 to 7.
HOLD-DOWN READJUSTMENT
If the setting indicated in Step 2 of Hold-Down Operation Confi rmation
cannot be met, readjustment should be performed by altering the
resistance value of R530, R531 component marked with
X
.
3mA DC range
+
-
+
-
A
+
-
FBT
TP85
T503
FBT
TP85
R531 R530
DC Power Supply
digital multimeter
ammeter
F
igure
1
3-2. B+ VOLTAGE CONFIRMATION AND
ADJUSTMENT
Always perform the following adjustments when replacing the following
components, which are marked with
Y
on the schematic diagram on
the GK Board:
G
K
BOARD:
IC600, PH602
1. Using a Variac, apply AC input voltage: 130 + 2.0/-0.0 VAC
2. Input a monoscope signal.
3. Set the PICTURE control and the BRIGHT control to
minimum.
4. Confi rm the voltage on A Board between TP23 and ground is less
than 136.5 VDC.
5. If step 4 is not satisfi ed, replace R530 and R531 on A Board and
repeat the above steps.
SECTION 3: SAFETY RELATED ADJUSTMENTS
Summary of Contents for FD Trinitron WEGA KV-27FS100
Page 76: ......
Page 80: ...User Guide ...
Page 82: ......
Page 98: ......
Page 120: ......
Page 131: ......
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......
Page 136: ......
Page 137: ......
Page 138: ...Sony Corporation Printed in U S A ...
Page 140: ...User Guide ...
Page 146: ......
Page 152: ......
Page 162: ......
Page 166: ......
Page 182: ......
Page 190: ......
Page 192: ......
Page 193: ......
Page 194: ......
Page 195: ......
Page 196: ......
Page 197: ......
Page 198: ......
Page 199: ......
Page 200: ......
Page 201: ......
Page 202: ...User Guide Sony Corporation Imprimé aux États unis ...
Page 204: ...Manual de instrucciones ...
Page 208: ...Manual de instrucciones ...
Page 210: ......
Page 226: ......
Page 250: ...Manual de instrucciones Corporación Sony Impreso en EE UU ...