— 19 —
KV-20FS12/20FV12/21FE12/A/C/21FM12/21FV12/C
SECTION 4
SAFETY RELATED ADJUSTMENTS
4-1.
R562 CONFIRMATION METHOD
(HV HOLD-DOWN CONFIRMATION) AND
READJUSTMENTS
The following adjustments should always be performed when
replacing the following components which are marked with on
the schematic diagram:
Preparation Before Confirmation
1. Using a Variac, apply AC input voltage: 120-220 ± 2 VAC.
2. Turn the POWER switch ON.
3. Input a white signal and set the PICTURE and
BRIGHTNESS controls to maximum.
4. Confirm that the voltage between C546 (+) or TP503
and ground is more than 97 VDC.
Hold-Down Operation Confirmation
1. Connect the current meter between Pin 11 of the FBT
(T505) and the PWB land where Pin 11 would normally
attach. (See Figure 1 on the next page.)
2. Input a dot signal and set PICTURE and BRIGHTNESS
to minimum: IABL = 100 ± 100
µ
A.
3. Confirm the voltage of A Board TP-600 is 135 ± 1 VDC.
4. Connect the digital voltmeter and the DC power supply
via diode 1SS119 to C546 (+) and ground. (See Figure 1
on the next page.)
5. Increase the DC power voltage gradually until the picture
blanks out.
6. Turn DC power source off immediately.
7. Read the digital voltmeter indication
(standard < 115.7 VDC).
8. Input a white signal and set PICTURE and BRIGHTNESS to
maximum: IABL = 1350 ± 100
µ
A.
9. Repeat steps 4 to 7.
Hold-Down Readjustment
If the setting indicated in step 2 of Hold-Down Operation
Confirmation cannot be met, readjustment should be performed by
altering the resistance value of R562 component marked with .
+
IABL
ABL
T505
FBT
range
-
ammeter
3.0 mA DC
A
4-2. B+ VOLTAGE CONFIRMATION AND
ADJUSTMENT
Note: The following adjustments should always be performed
when replacing the following components, which are marked with
on the schematic diagram on the A Board.
A BOARD:
IC601, PH601
1. Using a Variac, apply AC input voltage: 130 ± 2 VAC.
2. Input a dot signal.
3. Set the PICTURE and BRIGHTNESS controls to minimum.
4. Confirm that the voltage of A Board TP-600 is <136 VDC.
5. If step 3 is not satisfied, replace the components listed above,
then repeat steps 1–3.
Part Replaced ( ) Adjustment ( )
DY, T505, CRT, IC1301, IC501,
C507, C520, C505, C509, C515,
T504, L508, C551, L510, C546,
C537, C547, D517, D518, D519,
R560, R561, R562, R563, R565,
R566, R567, R525 ..........A B
oard
HV HOLD-DOWN
R562