Basic Functions
FCB-EH6500(GB) A-EEP-100-11(1)
1
Example: 8x 01 04 78 00 00 00 03 00 07 FF
The mask color of Mask_A and Mask_B is White
(color code 07h), and the mask color of the other
Mask (C to X) is Black (color code 00h).
Set Pan Tilt Angle
Command: 8x 01 04 79 0p 0p 0p 0q 0q 0q FF
Parameter:
ppp
Pan Angle
qqq
Tilt Angle
See “Setting pan/tilt angle” in “Parameters” on
page 19.
Comments: Pan/Tilt angle settings are hexadecimal
data.
The resolution of Pan/Tilt angle is 0.088 degrees.
Notes
• When you set the pan/tilt angle, locate the pan/tilt position at
the center point of the FCB camera’s position.
• If you set the pan/tilt angle or zoom the camera, a bigger mask
will be displayed for about one second.
Set PTZ Mask
Command: 8x 01 04 7B mm 0p 0p 0p 0q 0q 0q 0r 0r
0r 0r FF
Parameter:
mm Setting Mask
See “mm: Mask setting list” in “Parameters” on page 18
ppp
Pan Angle (000 to FFF)
See “Setting pan/tilt angle” in “Parameters” on page 19.
qqq
Tilt Angle (000 to FFF)
See “Setting pan/tilt angle” in “Parameters” on page 19.
rrrr
Zoom Position (000 to 4000)
See “Zoom Ratio and Zoom Position (for reference)” on
page 53.
Comments: Mask can be set at the desired position
by setting the pan tilt angle and zoom position
using this command. The set value can be input by
hexadecimal number.
Note
Privacy mask zone follows the change of angle of view according
to zoom. However, the follow might be delayed for a moment if
there is any big change, such as when using D-Zoom or E-FLIP.
Non Interlock Mask
Command: 8x 01 04 6F mm 0p 0p 0q 0q 0r 0r 0s 0s
FF
Parameters:
mm Setting Mask
See “mm: Mask setting list” in “Parameters” on page 18.
pp
Sets the center position “x” of the Mask on screen.
Sets the center position “y” of the Mask on screen.
rr
Sets the half value “w” of the Mask Width.
ss
Sets the half value “h” of the Mask Height.
See “pp: x, qq: y, rr: w, ss: h” in “Parameters” on page 18.
Commands: Mask does not interlock with pan/tilt.
The limitations of parameters are as follows.
(hexadecimal representation)
x: ±50h
w: ±50h
y: ±2Dh
h: ±2Dh
Note
When the Set Mask command and the Non Interlock Mask
command are set to the same mask, the command set later
becomes effective.
Parameters
mm: Mask setting list
Mask Name
mm (Hex)
Mask Name
mm (Hex)
Mask_A
00h
Mask_M
0Ch
Mask_B
01h
Mask_N
0Dh
Mask_C
02h
Mask_O
0Eh
Mask_D
03h
Mask_P
0Fh
Mask_E
04h
Mask_Q
10h
Mask_F
05h
Mask_R
11h
Mask_G
06h
Mask_S
12h
Mask_H
07h
Mask_T
13h
Mask_I
08h
Mask_U
14h
Mask_J
09h
Mask_V
15h
Mask_K
0Ah
Mask_W
16h
Mask_L
0Bh
Mask_X
17h
nn:Setting
nn
Setting
00
Resetting the zone size (the value of w,h)
for the existing mask.
01
Setting newly the zone size (the value of w,h).
pp: x, qq: y, rr: w, ss: h
160
90
0
h
(x,y)
w
B0h
D3h
2Dh
50h
mask
Effective display area