55
D30/31 Mode
EVI-D30/D31
EVI-D70/P
Parameters
Gain (dB)
Parameters
Gain (dB)
0000h
-3
b
0000h
-3
0001h
0
b
0001h
0
0002h
3
b
0003h
4
0003h
6
b
0004h
6
0004h
9
b
0006h
10
0005h
12
b
0007h
12
0006h
15
b
0009h
16
0007h
18
b
000Ah
18
Gain Conversion
• Parameter conversion when a command is received
D30/D31 parameters are converted to D70/P
parameters according to the table below.
EVI-D30/D31
EVI-D70/P
Parameters
Iris
Parameters
Iris
0000h
CLOSE
b
0000h
CLOSE
0001h
F28
b
0001h
F22
0002h
F22
b
0001h
F22
0003h
F19
b
0002h
F19
0004h
F16
b
0003h
F16
0005h
F14
b
0004h
F14
0006h
F11
b
0005h
F11
0007h
F9.6
b
0006h
F9.6
0008h
F8
b
0007h
F8
0009h
F6.8
b
0008h
F6.8
000Ah
F5.6
b
0009h
F5.6
000Bh
F4.8
b
000Ah
F4.8
000Ch
F4
b
000Bh
F4
000Dh
F3.4
b
000Ch
F3.4
000Eh
F2.8
b
000Dh
F2.8
000Fh
F2.4
b
000Eh
F2.4
0010h
F2
b
000Fh
F2
0011h
F1.8
b
0010h
F1.6
Iris conversion
• Parameter conversion when a command is received
D30/D31 parameters are converted to D70/P
parameters according to the table below.
• Parameter conversion when query commands are
received
D70/P parameters are converted to D30/D31
parameters and sent back.
• Parameter conversion when query commands are
received
D70/P parameters are converted to D30/D31
parameters and sent back.