5-70
DSR-45/45P
A
H
24. Component E-E CB Signal Level Adjustment
(VD-032 Board)
Mode
E-E
Signal
Color bar (NTSC: with 7.5% setup)
(COMPONENT input) (Note)
Measurement Point
COMPONENT OUT B-Y terminal
(75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
E
Adjustment Address
95
Specified Value
A = 700
±
10 mVp-p (NTSC)
A = 525
±
10 mVp-p (PAL)
Note:
Set “COMPONENT” mode with INPUT SELECT switch
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: E, address: 95, change the data and adjust the
component CB signal level (A) to the specified value.
3) Press the PAUSE button of the adjustment remote commander.
4) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-30