2-10
DSC-P8
2-13.BARRIER UNIT
[BARRIER OPERATION TEST METHOD]
After the barrier unit is replaced, check the following items with turning the power of the set ON/OFF.
• The lens moves out and the barrier shutters open completely when the power is turned on.
• The lens moves in and the barrier shutters close completely when the power is turned off.
Checking condition is
1
downward
2
45
°
downward
3
horizontal
4
45
°
upward
5
upward; totally five positions
and check three times for each position.
The test needs to be performed only when the barrier unit is replaced.
No performance of this test is needed when the lens is replaced.
1
downward
2
45
°
downward
3
horizontal
4
45
°
upward
5
upward
3X
3X
3X
3X
3X
1
Switch on a power supply.
3
Switch off a power supply by taking out a battery
or cut off a power supply from AC daptor.
(without using camera's power swich)
4
Pinch
A
portion with finger
and fit a driver over a hollow.
A
2
Push zoom button and transform the lens
as shown below.
5
Ornamental fixed plate (A)
7
Barrier unit
6
Two screws
(M1.4
×
4.5)
Summary of Contents for DSC-P8 - Cyber-shot Digital Still Camera
Page 16: ...2 9 DSC P8 2 12 JK 244 BOARD 3 Claw 1 Two claws 2 Boss 4 JK 244 board ...
Page 29: ...Schematic diagram of the SY 83 board are not shown Pages from 4 9 to 4 28 are not shown ...
Page 38: ...Printed wiring board of the SY 83 board are not shown Pages from 4 43 to 4 46 are not shown ...
Page 43: ...Waveforms of the SY 83 board are not shown Page 4 55 is not shown ...
Page 46: ...Mounted parts location of the SY 83 board are not shown Page 4 58 59 is not shown ...
Page 48: ...Mounted parts location of the JK 243 board are not shown Page 4 61 is not shown ...
Page 58: ...DSC P8 80 Sony EMCS Co 2003C0500 1 2003 3 Published by DI Customer Center 9 876 226 31 ...