1-2
ENGLISH
JAPANESE
ENGLISH
JAPANESE
DSC-H10_L2
1-2-3. Self-diagnosis Code Table
C
C
E
E
E
E
E
E
E
E
E
Block
Function
1
3
3
2
6
1
6
1
6
2
6
2
6
2
6
2
6
2
9
1
9
2
Detailed
Code
0
1
0
1
0
0
1
0
0
2
1
0
1
1
1
2
2
0
0
1
0
0
Symptom/State
The internal memory has experienced a
format error.
“Memory Stick Duo” is unformatted.
“Memory Stick Duo” is broken.
“Memory Stick Duo” type error
The camera cannot read or write data
on the “Memory Stick Duo”.
Trouble with hardware
Difficult to adjust focus
(Cannot initialize focus)
Zoom operations fault
(Cannot initialize zoom lens.)
Abnormality of IC for steadyshot.
Lens initializing failure.
Lens overheating (PITCH).
Lens overheating (YAW).
Abnormality of thermistor.
Abnormality when flash is being charged.
Non-standard battery is used.
Self-diagnosis Code
Repaired b
y:
Correction
Format the internal memory.
Format the “Memory Stick Duo”.
Insert a new “Memory Stick Duo”.
Insert a supported “Memory Stick Duo”.
Turn the power off and on again, or taking out and inserting the
“Memory Stick Duo” several times.
Turn the power off and on again.
Retry turn the power on by the power switch. If it does not
recover, check the focus reset sensor of lens block (pin
wj
of
CN402 on the SY-210 board). If it is OK, check the focus motor
drive IC (IC401 on the SY-210 board).
Retry turn the power on by the power switch. Check the zoom
reset sensor of lens block (pin
qj
of CN402 on the SY-210
board), if zooming is performed when the zoom button is
operated. If it is OK, check the zoom motor drive IC (IC401 on
the SY-210 board).
Check or replacement of the IC for steadyshot (IC501 on the SY-
210 board).
Check or replacement of the IC for steadyshot (IC501 on the SY-
210 board).
Check the HALL element (PITCH) of optical image stabilizer
(pin
2
,
3
of CN401 on the SY-210 board). If it is OK, check
PITCH/YAW angular velocity sensor (SE502 on the SY-210
board) peripheral circuits.
Check the HALL element (YAW) of optical image stabilizer (pin
6
,
7
of CN401 on the SY-210 board). If it is OK, check
PITCH/YAW angular velocity sensor (SE501 on the SY-210
board) peripheral circuits.
Replacement of lens block.
Checking of flash unit or replacement of flash unit. (Note)
Use the compatible battery only.
Note:
After repair, be sure to perform “1-3. PROCESS AFTER FIXING FLASH ERROR”.