1-6
39
English
Resizing the picture
Press the H/V SIZE +/– buttons to resize the picture.
V SIZE +: to expand vertical size
V SIZE –: to reduce vertical size
H SIZE +: to expand horizontal size
H SIZE –: to reduce horizontal size
The size of the picture is indicated on the screen by the
adjustment bar and value 0 to 100. The factory preset value is
50 (except the HDTV or 64 k input).
Aspect ratio display
As the picture size changes by the H/V SIZE button, the unit
calculates the aspect ratio of the converted picture and displays
it in decimal values on the screen together with the adjustment
bar and value.
Example:
4 : 3 is displayed 1.33 : 1
16 : 9 is displayed 1.78 : 1
Note
The aspect ratio is displayed only when a preset signal is input.
If an HDTV signal is input, the aspect ratio is displayed based
on the Japanese HDTV standard (1920
×
1035). For the preset
signals, see page 49.
Restoring the original picture size and position
Use GEOM RESET on the MENU 1 screen. (See page 41.)
Zooming and resizing the picture
You can zoom up the picture making it 2 , 3 or 4 times larger
than the original size.
You can also shift the position of the picture so that it fits in the
screen, or adjust the vertical and horizontal size of the picture
separately.
The adjustments can be carried out for the three inputs
separately.
Zooming up the picture
1
Display the picture on the screen.
2
Press the ZOOM + button.
Each time you press the ZOOM + button, the picture is
magnified by 2, 3 and 4 times respectively.
To zoom down, press the ZOOM – button.
3
Adjust the position of the close-up picture by pressing
the CENT
◊
/
√
/
ı
/
∫
buttons.
◊
/
√
: to shift the picture upward/
downward (V CENT)
ı
/
∫
: to shift the picture to the
right/left (H CENT)
The position of the picture is indicated on the screen by the
adjustment bar and value 0 to 100. The factory preset value is
50.
2
3
H/V SIZE buttons
ZOOM – button
NTSC
NTSC
IN
OUT
PAL
PAL
31.5k
31.5k
37k
37k
48k
48k
64k
OTHERS
64k
1080i
SIGNAL FORMAT
CHROMA
CONTRAST
APERTURE
OUTPUT
FORMAT
LINE
DOUBLER
OVER FLOW
STILL
OPEN
SCAN CONVERTER DSC-1024HD
INPUT SELECT
PHASE
1
2
3
TEST
PATTERN
DISPLAY
ON/OFF
TV
PJ
OFF
COMMAND
MODE
ON/OFF
MENU
ENTER
CENT
ZOOM
SIZE
V
V
H
H
S
GEN-LOCK
ZOOM
ZOOM x1
z
x2 x3 x4
CENT
V CENT
50
H CENT
50
SIZE
V
V
H
H
V SIZE
50
H SIZE
50
H SIZE
75
ASPECT 1.33:1
40
You can store the parameters of the adjusted picture into
memory. Five sets of input/output selection, zooming size,
H/V size and H/V position can be stored into memory and
switched quickly.
Up to 5 memories are available.
Storing the current condition
1
Adjust the picture as necessary.
2
Press the MENU button.
The MENU 1 screen appears.
3
Press the CENT
◊
/
√
button to move the cursor (
z
) to
MEM SAVE, and press the ENTER button.
The MEM SAVE screen appears.
The current data is displayed on the left column under
“CURRENT” and the data in the memory on the right
column. If no data is stored in the memory, that item is
shown by “– .”
.
4
Press the CENT
◊
/
√
button repeatedly so that the
desired memory number (1 to 5) appears.
5
Press the ENTER button.
The current data is stored under the selected memory
number on the right column.
If any data has been stored in the selected memory
number, it is now displayed on the left column under
“CURRENT.”
6
To quit the menu, press the MENU button three times.
Calling up the stored data
1
Press the MENU button.
The MENU 1 screen appears.
2
Press the CENT
◊
/
√
button to move the cursor (
z
) to
MEM LOAD, and press the ENTER button.
The MEM LOAD menu appears.
3
Press the CENT
◊
/
√
button repeatedly to select the
desired memory number (1 to 5), and press the ENTER
button.
The converter is adjusted to the selected memory data.
4
To cancel the operation, press the MENU button twice.
To call up the stored data quickly
Use the remote commander. See “Direct memory loading” on
page 42.
Using the memory
MENU button
ENTER button
CENT
◊
/
√
buttons
Current data
Memory number
Current data stored
NTSC
NTSC
IN
OUT
PAL
PAL
31.5k
31.5k
37k
37k
48k
48k
64k
OTHERS
64k
1080i
SIGNAL FORMAT
CHROMA
CONTRAST
APERTURE
OUTPUT
FORMAT
LINE
DOUBLER
OVER FLOW
STILL
OPEN
SCAN CONVERTER DSC-1024HD
INPUT SELECT
PHASE
1
2
3
TEST
PATTERN
DISPLAY
ON/OFF
TV
PJ
OFF
COMMAND
MODE
ON/OFF
MENU
ENTER
CENT
ZOOM
SIZE
V
V
H
H
S
GEN-LOCK
MENU
MENU 1
z
MEM LOAD
MEM SAVE
GEOM RESET
COLOR RESET
ALL RESET
INDEX NO.
LANGUAGE
USE: ENTER NEXT:MENU
ENTER
CENT
MEM SAVE
CURRENT
z
MEMORY1
INPUT
SIGNAL
OUTPUT
ZOOM
HSIZE
HCENT
VSIZE
VCENT
USE: ENTER CANCEL:MENU
VIDEO1
NTSC
31.5k
x1
50
50
50
50
–
–
–
–
–
–
–
–
CENT
MEM SAVE
CURRENT
z
MEMORY3
INPUT
SIGNAL
OUTPUT
ZOOM
HSIZE
HCENT
VSIZE
VCENT
USE: ENTER CANCEL:MENU
VIDEO1
NTSC
31.5k
x1
50
50
50
50
–
–
–
–
–
–
–
–
ENTER
MEM SAVE
CURRENT
z
MEMORY3
INPUT
SIGNAL
OUTPUT
ZOOM
HSIZE
HCENT
VSIZE
VCENT
USE: ENTER CANCEL:MENU
VIDEO1
NTSC
31.5k
x1
50
50
50
50
VIDEO1
NTSC
31.5k
x1
50
50
50
50
MEM LOAD
MEMORY1
z
CURRENT
INPUT
SIGNAL
OUTPUT
ZOOM
HSIZE
HCENT
VSIZE
VCENT
USE: ENTER CANCEL:MENU
VIDEO1
NTSC
31.5k
x1
50
50
50
50
VIDEO2
NTSC
64k
x2
50
80
60
80
Summary of Contents for DSC-1024HD
Page 20: ...DSC 1024HD 3 5 MEMO ...