5
Decoder
The air intake filter of the SDDS decoder must be kept clean at all times to avoid
that clogging stops the airflow.
Open the front panel of the DFP-2000 decoder and remove the air filter in the front panel
door, clean it and re-insert it.
How often this must be done depends on the density of dust in the air in your projection
room.
A clean working environment will contribute to making this procedure necessary on a
quarterly basis only.
Service procedure
The following service procedure is required and should be performed yearly by your qualified
service personnel.
•
Checking and adjusting the Video level of the SDDS reader, changing LED’s if necessary.
•
Checking the SDDS error rate using a calibrated SDDS alignment film.
•
Confirming that all reader rollers and other mechanical parts are in working order and
replace if necessary
•
Check that the channel levels and frequency response are correct
•
Securing system settings and replacing the SRAM battery (every 2
nd
year only)
↑↑