5-44
Fig. 5-3-4.
3. Battery End Adjustment
Set the battery end voltage.
If the voltage is incorrect, the life of the battery will shorten.
The image at the battery end will also be rough.
Mode
Camera recording
Subject
Arbitrary
Measurement Point
Display data of page: 2, address: 5D
Measuring Instrument
Adjustment remote commander
Adjustment Page
D
Adjustment Address
48 to 4C
Switch setting
1)
AUTO FOCUS ................................................................. OFF
Connection:
1)
Connect the regulated power supply and the digital voltmeter
to the battery terminal as shown in Fig. 5-3-4.
Preparations before adjustments:
1)
Adjust the output voltage of the regulated power supply so that
the digital voltmeter display is 6.1 ± 0.1Vdc.
2)
Turn off the power supply.
3)
Turn on the HOLD switch of the adjustment remote
commander.
4)
Turn on the power supply.
5)
Load a cassette, and set to the camera recording mode.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
Decrease the output voltage of
the regulated power supply so
that the digital voltmeter display
is 5.50 ± 0.01Vdc.
3
2
5D
Read the data, and this data is
named Dref.
4
D
48
Dref
Set the data, and press PAUSE
button.
5
Convert Dref to decimal
notation, and obtain Dref'.
(Note1)
6
Calculate D
49
', D
4A
', D
4B
' and D
4C
'
using following equations.
(decimal calculation)
D
49
' =Dref' + 7
D
4A
' =Dref' + 25
D
4B
' =Dref' + 29
D
4C
' =Dref' + 37
7
Convert D
49
', D
4A
', D
4B
' and D
4C
'
to decimal notation, and obtain
D
49
, D
4A
, D
4B
and D
4C
. (Note1)
8
D
49
D
49
Set the data, and press PAUSE
button.
9
D
4A
D
4A
Set the data, and press PAUSE
button.
10
D
4B
D
4B
Set the data, and press PAUSE
button.
11
D
4C
D
4C
Set the data, and press PAUSE
button.
12
0
01
00
Set the data.
Note1:
Refer to Table 5-4-1. “Hexadecimal-decimal conversion table” of
“5-4.Service mode”.
+
+
Regulated power supply
Digital volt meter
5.5
±
0.01 Vdc
+
Summary of Contents for DCR-VX2000E
Page 10: ...1 2 ...
Page 11: ...1 3 ...
Page 12: ...1 4 ...
Page 13: ...1 5 ...
Page 14: ...1 6 ...
Page 15: ...1 7 ...
Page 16: ...1 8 ...
Page 17: ...1 9 ...
Page 18: ...1 10 ...
Page 19: ...1 11 ...
Page 20: ...1 12 ...
Page 21: ...1 13 ...
Page 22: ...1 14 ...
Page 23: ...1 15 ...
Page 24: ...1 16 ...
Page 25: ...1 17 ...
Page 26: ...1 18 ...
Page 27: ...1 19 ...
Page 28: ...1 20 ...
Page 29: ...1 21 ...
Page 30: ...1 22 ...
Page 31: ...1 23 ...
Page 32: ...1 24 ...
Page 33: ...1 25 ...
Page 34: ...1 26 ...
Page 35: ...1 27 ...
Page 36: ...1 28 ...
Page 37: ...1 29 ...
Page 38: ...1 30 ...
Page 39: ...1 31 ...
Page 40: ...1 32 ...
Page 41: ...1 33 ...
Page 42: ...1 34 ...
Page 43: ...1 35 ...
Page 44: ...1 36 ...
Page 45: ...1 37 ...
Page 46: ...1 38 ...
Page 47: ...1 39 ...
Page 48: ...1 40 ...
Page 49: ...1 41 ...
Page 50: ...1 42 ...
Page 51: ...1 43 ...
Page 52: ...1 44 ...
Page 53: ...1 45 ...
Page 54: ...1 46 ...
Page 55: ...1 47 ...
Page 56: ...1 48 ...
Page 57: ...1 49 ...
Page 58: ...1 50 ...
Page 59: ...1 51 ...
Page 60: ...1 52 ...
Page 61: ...1 53 ...
Page 62: ...1 54 ...
Page 63: ...1 55 ...
Page 64: ...1 56 ...
Page 65: ...1 57 ...
Page 66: ...1 58 ...
Page 67: ...1 59E ...