6-17
DSC-P72
4. Picture Frame Setting
Mode
STILL (
)
Subject
Color bar chart and clear chart
(Standard picture frame)
About 30 cm from the front of the lens
Measurement Point
Video terminal of A/V OUT jack
Measuring Instrument
Oscilloscope and TV monitor
Specified Value
A=C=B/2, E=F
Switch setting:
ZOOM .................................................................... WIDE end
CAMERA setting (Menu setting) ................................ AUTO
Setting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting during
Camera System Adjustments” is
performed.
2
Shoot the color bar chart with the
zoom WIDE end.
3
Adjust the direction and distance
between the pattern box and
camera, and set the picture
frame to the specified position.
4
Remove the color bar chart and set
the clear chart.
5
Check that the whole of the
screen is white. If not, adjust the
direction and distance slightly.
6
10
44
Read the data, and this data named
YH.
7
10
45
Read the data, and this data named
YL.
8
60
2C
01
Write the data.
9
Perform the following adjustments.
How to reset the zoom and focus when they deviated:
If the zoom and focus deviated due to some reason reset them in the
following method.
Order Page Address Data
Procedure
1
60
2C
01
Write the data.
2
60
90
00
Write the data.
3
60
91
00
Write the data.
4
60
92
YL
Write the data. Note
5
60
93
YH
Write the data. Note
6
60
01
79
Write the data.
7
Wait until the movement of the
lens stops.
8
60
07
Read the data, and check it is “01”.
9
60
01
00
Write the data.
Note:
YH and YL are the data read in the “Setting method”.
Check on an oscilloscope
1. Horizontal period
Fig. 6-1-10.
2. Vertical period
Fig. 6-1-11.
Check on the monitor TV (Underscanned mode)
Fig. 6-1-12.
E=F
V
E
F
Color bar chart picture frame
Effective picture frame
A
B
C
B
A
C
A = C =
B