DSC-HX7/HX7V_L2
1-3
– ENGLISH –
1-5. PROCESS AFTER FIXING FLASH ERROR
When “FLASH error” (Self-diagnosis Code E : 91 : 01) occurs, to prevent any abnormal situation caused by high voltage, setting of the flash is changed
automatically to disabling charge and flash setting.
After fixing, this setting needs to be deactivated. Flash error code can be on the HOME screen.
Method for Initializing the Flash Error Code
Reset Flash Error using the Flash Error Repair Tool Ver_[].[].exe.
1-4-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
C
1
3
0
1
The internal memory has experienced a me-
dia error.
Turn the power off and on again.
The internal memory has experienced a for-
mat error.
Format the internal memory.
Memory card is unformatted.
Format the memory card.
Memory card is broken.
Insert a new memory card.
Memory card type error
Insert a supported memory card.
The camera cannot read or write data
on the
memory card.
Turn the power off and on again, or taking out and inserting the memory
card several times.
C
3
2
0
1
Trouble with hardware
Turn the power off and on again.
E
6
1
0
0
Difficult to adjust focus
(Cannot initialize focus)
Retry turn the power on by the power switch. If it does not recover,
check the focus reset sensor of lens block (pin
6
of CN401 on the
SY-283 board). If it is OK, check the focus motor drive IC (IC401 on
the SY-283 board).
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
Retry turn the power on by the power switch. Check the zoom reset
sensor of lens block (pin
0
of CN401 on the SY-283 board) when
zooming is performed when the zoom button is operated. If it is OK,
check the zoom motor drive IC (IC401 on the SY-283 board).
E
6
2
0
2
Abnormality of IC for steadyshot.
Check of the IC for steadyshot (IC401 on the SY-283 board).
E
6
2
1
0
Lens initializing failure.
Check of the IC for steadyshot (IC401 on the SY-283 board).
E
6
2
1
1
Lens overheating (PITCH).
Check the HALL element (PITCH) of optical image stabilizer (pin
rk
,
t;
of CN401 on the SY-283 board). If it is OK, check PITCH angular
velocity sensor (SE401 on the SY-283 board) peripheral circuits.
E
6
2
1
2
Lens overheating (YAW).
Check the HALL element (YAW) of optical image stabilizer (pin
ef
,
eh
of CN401 on the SY-283 board). If it is OK, check YAW angular
velocity sensor (SE401 on the SY-283 board) peripheral circuits.
E
6
2
2
0
Abnormality of thermistor.
Check the OIS temp sensor of optical image stabilizer (pin
qs
of
CN401 on the SY-283 board).
E
9
1
0
1
Abnormality when flash is being charged.
Checking of flash unit or replacement of flash unit. (Note)
E
9
4
0
0
Internal memory fault
Inspect the internal memory (IC201 on the SY-283 board).
E
9
5
0
0
GPS hardware error
Check whether the FP-1395 flexible board of connected between AT-
042 board and RL-108 board or RL-099 flexible board of connected
between SY-283 board and RL-108 board is broken, and check whether
it is inserted imperfectly.
If there is no problem the coaxial cable or flexible board, inspect or
replacement of the AT-042 or RL-108 board.
Note:
After repair, be sure to perform “1-5. PROCESS AFTER FIXING FLASH ERROR”.
The changed portions from