CXD5602 User Manual
-
920/1010
-
Area
Select
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
bit
Input Address
Output Address
Conversion Setting Registers
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
bit
3 2 1 0
0 0 0 0 0 0 0 0 0 0 0 0
0 0 0 0
0
Area Select
Value for Area0
Value for Area1
Value for AreaF
0x0
0x1
0xF
Conversion enabled when the
address is 1MB from the
beginning.
Address[15:0]
5 4
6
00
:
Reserved
01
:
SYS Window
10
:
GNS Window
11
:
APP Window
7
9 8
10
Start Window 32MB Area
Figure APP-108 Address Conversion Operation Scheme
Timing control function of reflecting the address converter setting is not equipped. For this reason, set value
change must be performed during the period that there are no bus transactions of the target ADSP between the
address area before conversion and the address area after conversion. Any accesses to undefined addresses are
prohibited.
Table APP-790 shows address conversion registers.
Summary of Contents for CXD5602
Page 1: ...CXD5602 User Manual 1 1010 CXD5602 User Manual ...
Page 36: ...CXD5602 User Manual 36 1010 2 3 Block Diagram Figure Block Diagram 1 CXD5602 Block Diagram ...
Page 144: ...CXD5602 User Manual 144 1010 GNSS_RAMMODE_SEL 0x3F000FFF SRAM GNSS BB 0 5 ON ...
Page 835: ...CXD5602 User Manual 835 1010 enable disable ...