CX-JT9
50
50
6-29. SCHEMATIC DIAGRAM – TRANSFORMER BOARD – (E51 model)
The components identified by mark
0
or dotted
line with mark
0
are critical for safety.
Replace only with part number specified.
D902
D904
D905
D903
CN902
JW909
JW906
JW905
JW903
C901
D901
CN901
S901
C902
PT902
PT901
F902
RY901
F905
F906
1SS355
1SS355
1SS355
1SS355
11P
0.1
1SS355
2P
470
25V
T2.5AL
250V
T10AL
125V
T10AL
125V
VH(AC)
VH(AC)
GND
VL(AC)
VL(AC)
VM(AC)
VM(AC)
FIL-1
FIL-2
P-ON
EVER+10V
BUILT IN TRANSFORMER
NOT REPLACEABLE:
∗
230-240V
220V
120V
(AC IN)
VOLTAGE
-1
-2
SUB POWER TRANSFORMER
MAIN POWER TRANSFORMER
-2
-1
AC
(Page 42)