17
CSD-MP100
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T2
10.7 MHz
FM FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display
87.5 MHz
108 MHz
Reading on Digital voltmeter
1.3 ± 0.3 V
3.0 ± 0.2 V
Adjustment Part
<confirmation>
L2
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
CT1
87.5 MHz
108 MHz
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
450 kHz
AM FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display
530 kHz
1,710 kHz
(US, CND)
(US, CND)
531 kHz
1,611 kHz
(Except US, CND)
(Except US, CND)
Reading on
Digital voltmeter
1.0 ± 0.05 V
5.3 ± 0.7 V
Adjustment Part
L4
<confirmation>
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
CT3
620 kHz (US, CND)
1,400 kHz (US, CND)
621 kHz (Except US, CND)
1,404 kHz (Except US, CND)
digital
voltmeter
100 k
Ω
TP (VT)
Put the lead-wire
antenna close to
the set.
AM RF signal
generator
TP (FM IN)
FM RF signal
generator
0.01
µ
F
set
TUNER SECTION 0 dB = 1 µV
• FM Section
Setting:
BAND button: FM
75 kHz frequency
deviation by 1 kHz signal
output level : as low as possible
• AM Section
Setting:
BAND button: AM
30% amplitude
modulation by
400 Hz signal
• Connecting Level Meter (FM and AM)
• Connecting Digital Voltmeter (FM and AM)
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
Adjustment Location: See page 18.