— 20 —
•
Good Example
•
Incorrent Examples (DC level changes more than on adjusted
waveform)
5.
Connect the oscilloscope between TP (TE) and TP (VC).
6.
Insert disc (YEDS-18) and press the CD
^
button.
7.
Adjust RV704 so that the waveform is as shown in the figure
below. (tracking gain adjustment)
Incorrect Examples (fundamental wave appears)
VOLT/DIV : 0.1V
TIME/DIV : 2ms
0V
low focus gain
high focus gain
low tracking gain
high tracking gain
(high fandametial wave than for low gain)
25mV
0V
VOLT/DIV : 20mV
TIME/DIV : 1ms
VOLT/DIV : 20mV
TIME/DIV : 2ms
50mV
0V
VOLT/DIV : 100mV
TIME/DIV : 2ms
10mV
0V
VOLT/DIV : 0.1V
TIME/DIV : 2ms
0V
VOLT/DIV : 0.1V
TIME/DIV : 2ms
0V
[MAIN BOARD] (Component side)
TP(TO)
TP(T
O)
TP(FO)
TP(FO)
TP(VC)
TP(VC)
Osillloscope
(DC range)
+
–