![Sony CDP-XA50ES Service Manual Download Page 35](http://html.mh-extra.com/html/sony/cdp-xa50es/cdp-xa50es_service-manual_398414035.webp)
– 55 –
Pin No. Pin Name
I / O
Function
44
WDCK
O
Word clock signal (88.2 kHz) output terminal Not used (open)
45
LRCK
O
L/R sampling clock signal (44.1 kHz) output to the CXD8679Q (IC601)
46
DATA
O
DA16 output when PSSL=“H”, 48-bit slot serial data output when PSSL=“L”
(PSSL (pin
$£
)=fixed at “L”) Serial data output to the CXD8679Q (IC601)
47
BCLK
O
DA15 output when PSSL=“H”, 48-bit slot bit clock signal output when PSSL=“L”
(PSSL (pin
$£
)=fixed at “L”) Bit clock signal (2.8224 MHz) output to the CXD8679Q (IC601)
48
64 DATA
O
DA14 output when PSSL=“H”, 64-bit slot serial data output when PSSL=“L”
(PSSL (pin
$£
)=fixed at “L”) Not used (open)
49
64 BCLK
O
DA13 output when PSSL=“H”, 64-bit slot bit clock signal output when PSSL=“L”
(PSSL (pin
$£
)=fixed at “L”) Not used (open)
50
64 LRCK
O
DA12 output when PSSL=“H”, 64-bit slot L/R sampling clock signal output when PSSL=“L”
(PSSL (pin
$£
)=fixed at “L”) Not used (open)
51
GTOP
O
DA11 output when PSSL=“H”, GTOP signal output when PSSL=“L”
(PSSL (pin
$£
)=fixed at “L”) Not used (open)
52
XUGF
O
DA10 output when PSSL=“H”, XUGF signal output when PSSL=“L”
(PSSL (pin
$£
)=fixed at “L”) Not used (open)
53
XPLCK
O
DA09 output when PSSL=“H”, XPLCK signal output when PSSL=“L”
(PSSL (pin
$£
)=fixed at “L”) Not used (open)
54
GFS
O
DA08 output when PSSL=“H”, GFS (guard frame sync) signal output when PSSL=“L”
(PSSL (pin
$£
)=fixed at “L”) Not used (open)
55
RFCK
O
DA07 output when PSSL=“H”, RFCK (read frame clock) signal output when PSSL=“L”
(PSSL (pin
$£
)=fixed at “L”) Not used (open)
56
C2PO
O
DA06 output when PSSL=“H”, C2PO signal output when PSSL=“L”
(PSSL (pin
$£
)=fixed at “L”) Not used (open)
57
XRAOF
O
DA05 output when PSSL=“H”, XRAOF (RAM over flow) signal output when PSSL=“L”
(PSSL (pin
$£
)=fixed at “L”) Not used (open)
58
MNT3
O
DA04 output when PSSL=“H”, MNT3 (monitor 3) signal output when PSSL=“L”
(PSSL (pin
$£
)=fixed at “L”) Not used (open)
59
MNT2
O
DA03 output when PSSL=“H”, MNT2 (monitor 2) signal output when PSSL=“L”
(PSSL (pin
$£
)=fixed at “L”) Not used (open)
60
MNT1
O
DA02 output when PSSL=“H”, MNT1 (monitor 1) signal output when PSSL=“L”
(PSSL (pin
$£
)=fixed at “L”) Not used (open)
61
MNT0
O
DA01 output when PSSL=“H”, MNT0 (monitor 0) signal output when PSSL=“L”
(PSSL (pin
$£
)=fixed at “L”) Not used (open)
62
XTAI
I
System clock input terminal (16 MHz)
63
XTAO
O
System clock output terminal (16 MHz) Not used (open)
64
XTSL
I
System clock selection input terminal (fixed at “L”)
65
DVSS
—
Ground terminal (digital system)
66
FSTI
I
2/3 divider input terminal of pins
^™
(XATI) and
^£
(XTAO)
67
FSTO
O
2/3 divider output terminal of pins
^™
(XATI) and
^£
(XTAO)
68
C4M
O
4.2336 MHz clock signal output terminal Not used (open)
69
C16M
O
16.9344 MHz clock signal output terminal Not used (open)
70
MD2
I
Digital out on/off control signal input from the system controller (IC201)
71
DOUT
O
Digital signal (for coaxial out and optical out) output terminal
72
EMPH
O
Emphasis control signal output terminal Not used (open)
73
WFCK
O
Write frame clock signal output terminal Not used (open)
74
SCOR
O
Sub-code sync (S0+S1) detection signal output to the system controller (IC201)
Summary of Contents for CDP-XA50ES
Page 4: ... 4 SECTION 2 GENERAL This section is extracted from instruction manual ...
Page 5: ... 5 ...
Page 6: ... 6 ...
Page 7: ... 7 ...
Page 8: ... 8 ...
Page 9: ... 9 ...
Page 10: ... 10 ...
Page 11: ... 11 ...
Page 12: ... 12 ...
Page 13: ... 13 ...
Page 14: ... 14 ...
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ......
Page 30: ......
Page 31: ......