13
LOADING AGING MODE
• This mode is used for repeating loading operations continuously.
• Aging will be performed continuously unless an error occurs.
• When an error occurs, the error code will be displayed on the
fluorescent indicator tube.
Procedure:
1.
Set a disc in the DISC 1 slit.
2.
Turn on the power and press the GROUP FILE , MEGA
CONTROL and
1/u
buttons.
Rotate the DISC/CHARACTER dial, select “Table Roatation”
and press the dial.
3.
When the mode is set, both the
·
and
P
indicators will
start to blink.
4.
When the
·
button is pressed, only the
·
indicator will
blink and aging starts.
5.
To end the mode, press the
1/u
button or disconnect the
power cord from the outlet.
The error codes displayed during operations and when errors occur
are the same as the
“AGING MODE”
described earlier.
TABLE AGING MODE
• This mode is used for rotating the table randomly.
• Aging will be performed continuously unless an error occurs.
• When an error occurs, the error code will be displayed on the
fluorescent indicator tube.
Procedure:
1.
Turn on the power and press the GROUP FILE , MEGA
CONTROL and
1/u
buttons.
Rotate the DISC/CHARACTER dial, select “Table Aging”
and press the dial.
Rotate the DISC/CHARACTER dial and set the disk in the
slit whose number is being displayed (150, 149, 300, 1, 2)
2.
When the mode is set, both the
·
and
P
indicators will
start to blink.
3.
When the
·
button is pressed, only the
·
indicator will
blink and aging starts.
4.
To end the mode, press the
1/u
button or disconnect the
power cord from the outlet.
During aging, operations will be carried out sequentially in the order
of No. 1, No. 2, No. 150, No. 149, and No. 300 slits.
The error codes displayed during operations and when errors occur
are the same as the
“AGING MODE”
described earlier.
DOOR POP UP AGING MODE
• This mode is used for performing aging of the CD pop up part
and door open/close.
It is used for checking if operations are performed normally.
Method:
1.
Turn on the power and press the GROUP FILE , MEGA
CONTROL and
1/u
buttons.
Rotate the DISC/CHARACTER dial, select “Door Popup
Aging” and press the dial.
2.
Aging starts, and door open/close and up/down operations of
the pop up part are performed continuously.
3.
To end the mode, press the
1/u
button.
TABLE ROTATION MODE
• This mode is used for electrical adjustments. Refer to the section
on Electrical Adjustments.
TITLE MEMO SHIFT MODE
• This mode is used for writing title memo information recorded in
this unit in a different unit.
Use it for transferring disc memo contents written by the cus-
tomer to the new units when replacing the unit, etc.
Connection:
CONTROL A1
II
connection cord provided
Flow of data
This unit
(Copy source)
Another unit
(Copy destination)
COMMAND MODE: CD3
COMMAND MODE: CD1
CONTROL A1
II
$
$
$
$
Procedure:
1.
Connect two units using the CONTROL A1 II connection
cord shown in the figure.
2.
Set the COMMAND MODE switch of the copy source unit to
CD3 and the COMMAND MODE switch of the copy
destination unit to CD1 .
3.
With the power on, while pressing the GROUP 7 button and
§
OPEN/CLOSE button of the copy destination unit, press
the +100 button.
4.
When the data has been transferred, the fluorescent indicator
tube displays “complete” for about 1 second.
MODEL NAME DISPLAY
•
Model names can be displayed on the fluorescent indicator tube
for checking the microprocessor model setting, etc.
Procedure:
With the power ON, while pressing the GROUP FILE and MEGA
CONTROL buttons, press the
1/u
button.
Rotate the DISC/CHARACTER dial, select “Model Name”
and press the dial.
The model name is displayed on the fluorescent indicator tube.
Let the model name be displayed for three seconds and exit the
mode.
MICROPROCESSOR VERSION DISPLAY
•
The microprocessor version can be displayed on the fluorescent
indicator tube.
Procedure:
With the power ON, while pressing the GROUP FILE and MEGA
CONTROL buttons, press the
1/u
button.
Rotate the DISC/CHARACTER dial, select “Show Mcom Ver.”
and press the dial.
The microprocessor version is displayed on the fluorescent indicator
tube.
Let the model name be displayed for three seconds and exit the
mode.
ALL LIT MODE
•
This mode is used for lighting the whole fluorescent indicator
tubes and LEDs.
Procedure:
With the power ON, while pressing the GROUP FILE and MEGA
CONTROL buttons, press the
1/u
button.
Rotate the DISC/CHARACTER dial, select “All Lit Mode” and
press the dial.
Both the fluorescent indicator tubes and LEDs will light up
completely.
To end this mode, press the
1/u
mode.
Summary of Contents for CDP-CX400 - Compact Disc Player
Page 59: ...59 CDP CX400 CX450 MEMO ...