6-72
3-14. Y FM CARRIER FREQUENCY ADJUSTMENT
Purpose :
Adjusts the FM signal to be recorded on tape
to the 8 mm format. (Adjusts the carrier
frequency of normal mode Y FM signal.)
Adjustment error :
(If frequency is low) Overall picture will be
blurred signal. (If frequency is high) Overall
picture will have black streaking noise.
S/N will be deteriorated.
Mode
CAM-REC
Signal
Any signal
Measurement Point
IC201 pin
$¡
Measuring Instrument
Frequency counter, Oscilloscope
Adjustment Page
F
Adjustment Address
30
Specification Value
4.20
±
0.01MHz
Adjustment procedure:
Order
Page
Address
Data
Procedure
1
6
00
01
After setting the data, press the PAUSE button. (Preparation)
2
6
01
43
After setting the data, press the PAUSE button.
3
F
30
Change data using PLAY and STOP buttons so that the carrier frequency satisfies the
specification. (Record mode)
4
Press the PAUSE button.
5
6
01
00
After setting the data, press the PAUSE button.
6
6
00
00
After setting the data, press the PAUSE button. (End)
4.20
±
0.01MHz
Approx 0.5 Vp-p
Summary of Contents for CCD-TRV312 Operating Instructions (primary manual)
Page 8: ...1 2 ...
Page 9: ...1 3 ...
Page 10: ...1 4 ...
Page 11: ...1 5 ...
Page 12: ...1 6 ...
Page 13: ...1 7 ...
Page 14: ...1 8 ...
Page 15: ...1 9 ...
Page 16: ...1 10 ...
Page 17: ...1 11 ...
Page 18: ...1 12 ...
Page 19: ...1 13 ...
Page 20: ...1 14 ...
Page 21: ...1 15 ...
Page 22: ...1 16 ...
Page 23: ...1 17 ...
Page 24: ...1 18 ...
Page 25: ...1 19E ...
Page 66: ...312 TRV512 NTSC 4 73 4 74 page 4 66 for VF 109 BOARD printed wiring board ...
Page 72: ...53 TRV312 TRV512 NTSC age 4 89 for PD 76 BOARD printed wiring board 4 100 ...
Page 76: ...53 TRV312 TRV512 NTSC age 4 111 for PD 77 BOARD printed wiring board 4 110 ...