5-48
2. AFC f
0
Adjustment (VC-215 board)
Adjust the pull-in range of the A/D converted clock generator dur-
ing playback.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin
4
of CN910 (AFC f0)
Measuring Instrument
Digital voltmeter
Adjustment Page
F
Adjustment Address
4A
Specified Value
A = 2.10±0.05Vdc
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 4D, and press the PAUSE
button of the adjusting remote commander.
3) Select page: F, address: 4A, change the data and set the DC
voltage (A) to the specified value.
4) Press the PAUSE button of the adjusting remote commander.
5) Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
6) Select page: 0, address: 01, and set data: 00.
3-4.
VIDEO SYSTEM ADJUSTMENTS
Video system adjustments must be performed in the following order.
[Adjusting Order]
1.
28MHz origin oscillation adjustment
2.
AFC f
0
adjustment
3.
Filter f
0
adjustment
4.
Y OUT level adjustment
5.
C OUT level adjustment
6.
RP filter f
0
adjustment
7.
Hi8 REC Y current adjustment
8.
Standard REC Y current adjustment
9.
Hi8 REC L level adjustment
10. Standard8 REC L level adjustment
11. REC C current adjustment
Mode
VTR stop
Signal
No signal
Measurement Point
Pin
^§
of IC202 or pin
!™
of IC501
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
2C
Specified Value
Pin
^§
of IC202 :
f=4433593.75±17Hz
Pin
!™
of IC501 :
f=14187500±55Hz
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 2, address: 61, and set data: 30.
3) Select page: 3, address: 01, set data: 41, and press the PAUSE
button of the adjusting remote commander.
4) Select page: F, address: 2C, change the data and set the clock
frequency(f) to the specified value.
5) Press the PAUSE button of the adjusting remote commander.
6) Select page: 2, address: 61, and set data: 10.
7) Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
6) Select page: 0, address: 01, and set data: 00.
1. 28 MHz Origin Oscillation Adjustment (VC-215 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Summary of Contents for CCD-TRV26E
Page 12: ...1 2 ...
Page 13: ...1 3 ...
Page 14: ...1 4 ...
Page 15: ...1 5 ...
Page 16: ...1 6 ...
Page 17: ...1 7 ...
Page 18: ...1 8 ...
Page 19: ...1 9 ...
Page 20: ...1 10 ...
Page 21: ...1 11 ...
Page 22: ...1 12 ...
Page 23: ...1 13 ...
Page 24: ...1 14 ...
Page 25: ...1 15 ...
Page 26: ...1 16 ...
Page 27: ...1 17 ...
Page 28: ...1 18 ...
Page 29: ...1 19 ...
Page 30: ...1 20 ...
Page 31: ...1 21 ...
Page 32: ...1 22 ...
Page 33: ...1 23 ...
Page 34: ...1 24 ...
Page 35: ...1 25E ...