2. VCO Adjustment (PD-107 board)
Set the VCO freerun frequency. If deviated, the LCD screen will be
blurred.
Mode
VTR stop
Signal
No signal
Measurement point
Pin
2
of CN5501 (VCO VOLTAGE)
of PD-107 board
Measuring instrument
Oscilloscope
Adjustment page
E
Adjustment address
D6
Specified value
A = 2.75 ± 0.02V
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 55, and press the PAUSE
button of the adjusting remote commander.
3) Select page: 2, address: 7D, and set data: 00.
4) Select page: E, address: D6, change the data and set the VCO
VOLTAGE (A) to the specified value.
5) Press the PAUSE button of the adjusting remote commander.
6)
Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
7) Select page: 0, address: 01, and set data: 00.
Fig. 5-1-22.
3. D range Adjustment (PD-107 board)
Set the D range of the RGB decoder used to drive the LCD to the
specified value. If deviated, the LCD screen will become blackish
or saturated (whitish).
Note1 :
Press the DISPLAY button and erase the screen indictors
on the LCD screen.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 55, and press the PAUSE
button of the adjusting remote commander.
3) Select page: 2, address: 7D, and set data: 00.
4) Select page: E, address: D4, change the data and set the voltage
(A) between the reversed waveform pedestal and non-reversed
waveform pedestal to the specified value.
5) Press the PAUSE button of the adjusting remote commander.
6) Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
7) Select page: 0, address: 01, and set data: 00.
Mode
VTR stop
Signal
No signal
Measurement point
Pin
3
of CN5501 (VG) of PD-107
board
External trigger : Pin
4
of CN5501
(PANEL COM)
Measuring instrument
Oscilloscope
Adjustment page
E
Adjustment address
D4
Specified value
A = 3.62 ± 0.05V
Fig. 5-1-23.
H
A
GND level
(0 Vdc)
A
2H
Summary of Contents for CCD TRV16 - Hi8 Handycam Camcorder
Page 12: ......
Page 13: ......
Page 14: ......
Page 15: ......
Page 16: ......
Page 17: ......
Page 18: ......
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ......
Page 30: ......
Page 39: ......
Page 47: ...T901 T902 ...
Page 48: ...20 20 3 1V 3 1V 3 1V 3 1V 3 1V 3 1V 3 1V 3 1V 3 1V 3 1V 3 1V 3 1V ...
Page 49: ... TR MODEL COLOR EVF MODEL B W EVF MODEL ...
Page 50: ......
Page 55: ......
Page 56: ......
Page 57: ...REC PB ...
Page 58: ......
Page 59: ......
Page 60: ...51 52 ...
Page 61: ...55 53 54 56 ...
Page 63: ...63 62 ...
Page 67: ......
Page 70: ......
Page 74: ......
Page 75: ......
Page 77: ...3Vp p 7 2Vp p 7 5Vp p 7 6Vp p 3Vp p 3Vp p 3Vp p 3 4Vp p 2 7Vp p ...
Page 78: ......
Page 81: ...7 7 7 9 7 9 1 9 3 1 7 8 3 1 ...