5-41
3. Filter f
0
Adjustment (VC-234 board)
Adjust the f
0
frequency of the IC641 built-in filter.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin
3
of CN982 (IR VIDEO)
Measuring Instrument
Oscilloscope
(20 MHz BW LIMIT: ON)
Adjustment Page
F
Adjustment Address
66
Specified Value
Minimum residual chroma signal
components
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 01, set data: 4F, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 2, address: 05, and set data: 40.
4)
Select page: F, address: 66, change the data and minimize the
residual chroma signal components (A).
(The data of address: 66 should be “70” to “7F”.)
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: 2, address: 05, and set data: 00.
8)
Select page: 0, address: 01, and set data: 00.
4. Y OUT Level Adjustment (VC-234 board)
Set the Y signal output level. (Adjust the D/A converter out put
level of IC641.)
Mode
VTR stop
Signal
No signal
Measurement Point
Hi8 model:
Y signal terminal of S VIDEO
terminal (75
Ω
terminated)
Standard8 model:
VIDEO terminal (75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
67
Specified Value
A=300 ± 5mV
Note1:
Hi8 model:
Insert the plug into the S VIDEO terminal.
Standard8 model:
Insert the plug into the VIDEO terminal.
Note2:
Hi8 model:
CCD-TR717E/TR918E/TRV67E/TRV87E
Standard8 model:
CCD-TR317E/TR417E/TR427E/TR617E/TRV37E/TRV47E/
TRV48E/TRV57E
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 01, set data: 41, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 6, address: 61, and set data: 30.
4)
Select page: F, address: 67, change the data and set the SYNC
level (A) to the specified value.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 6, address: 61, and set data: 10.
7)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
8)
Select page: 0, address: 01, and set data: 00.
H
A
H
A
Fig. 5-3-7.
Fig. 5-3-8.
Hi8 model
Standard8 model
H
A
Summary of Contents for CCD-TR918E, CCD-TR717E, CCD-TR417E, CCD-TR427E, CCD-TR617E
Page 12: ...1 2 ...
Page 13: ...1 3 ...
Page 14: ...1 4 ...
Page 15: ...1 5 ...
Page 16: ...1 6 ...
Page 17: ...1 7 ...
Page 18: ...1 8 ...
Page 19: ...1 9 ...
Page 20: ...1 10 ...
Page 21: ...1 11 ...
Page 22: ...1 12 ...
Page 23: ...1 13 ...
Page 24: ...1 14 ...
Page 25: ...1 15 ...
Page 26: ...1 16 ...
Page 27: ...1 17 ...
Page 28: ...1 18 ...
Page 29: ...1 19 ...
Page 30: ...1 20 ...
Page 31: ...1 21 ...
Page 32: ...1 22 ...
Page 33: ...1 23 ...
Page 34: ...1 24 ...
Page 35: ...1 25E ...